| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 1.089 kW | |||
|---|---|---|---|
| 06/27/2026 10:13 (2222 days) | Production | Consumption | NET Usage |
| Now | 1.184 kW | 2.273 kW | 1.089 kW |
| Today | 3.638 kWh (0.355 kW) | 2.283 kWh (0.223 kW) | -1.355 kWh (-0.132 kW) |
| - This Week | 127.801 kWh (19.886 kWh/day) | 141.169 kWh (21.967 kWh/day) | 13.368 kWh (2.080 kWh/day) |
| - This Month | 787.447 kWh (29.796 kWh/day) | 628.025 kWh (23.764 kWh/day) | -159.422 kWh (-6.032 kWh/day) |
| - This Year | 3.522 MWh (19.850 kWh/day) | 3.198 MWh (18.024 kWh/day) | -0.324 MWh (-1.825 kWh/day) |
| Yesterday | 18.889 kWh (0.787 kW) | 17.732 kWh (0.739 kW) | -1.157 kWh (-0.048 kW) |
| Last 7 Days | 155.718 kWh (22.245 kWh/day) | 156.994 kWh (22.428 kWh/day) | 1.276 kWh (0.182 kWh/day) |
| Last 30 Days (05/28/2026) | 910.670 kWh (30.356 kWh/day) | 713.764 kWh (23.792 kWh/day) | -196.906 kWh (-6.564 kWh/day) |
| Last One Year | 6.696 MWh (18.344 kWh/day) | 7.732 MWh (21.182 kWh/day) | 1.036 MWh (2.838 kWh/day) |
| Lifetime Since PTO | 39.088 MWh (17.588 kW/day) | 42.709 MWh (19.217 kW/day) | 3.621 MWh (1.629 kW/day) |
| Lifetime Since Install | 39.121 MWh | 43.289 MWh | 4.167 MWh |
| Voltage/Current | 247.2 V / 4.8 A | 247.1 V / 9.2 A | 247.2 V / 4.4 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 05/09/2023 23:09 (13.9 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 28.977 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.922 | 2.173 | 10.940 | 0.000 kW 1.872 kWh |
0.000 kW 11.233 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.836 | 2.043 | 10.296 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.895 | 2.104 | 10.664 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.917 | 2.140 | 10.784 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.796 | 1.924 | 9.786 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.867 | 2.096 | 10.463 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.840 | 2.044 | 10.133 | 0.000 kW 1.843 kWh |
0.000 kW 9.214 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.823 | 1.959 | 10.025 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.296 | 1.831 | 1.986 | 10.071 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.848 | 2.041 | 10.201 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.296 | 1.871 | 2.078 | 10.341 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.260 | 1.678 | 1.977 | 10.261 | 0.000 kW 1.737 kWh |
0.000 kW 6.950 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.272 | 1.714 | 1.960 | 10.402 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.268 | 1.778 | 2.056 | 10.837 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.276 | 1.779 | 2.051 | 10.826 | |||
| wind | 16 - 202320****** | IQ7XS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.527 kWh |
0.000 kW 1.581 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.230 | 1.581 | 1.585 | 11.028 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.17 V | Current/Power | -7.90 A (-0.420 kW) |
| Remain Capacity/Energy | 477.0 Ah (24.4 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 79.5 % | State Of Health | 100.0 % |
| Run Time | 2d 12h 23m to empty | Report Date | 2023-05-09 23:58 |
|
|||
| Voltage | 53.20 V | Cell (MIN/MAX) | 3.320 V / 3.330 V (0.010 V) |
|---|---|---|---|
| Current/Power | -2.10 A (-111 W) | Runtime | 3d 3h 43m to empty |
| Remain Capacity/Energy | 159.0 Ah (8.1 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 79.5 % | State Of Health | 100.0 % |
| Temperature | 21.0 °C | Cycle | 99 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-09 23:58 |
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.321 V / 3.323 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.44 A (-76 W) | Runtime | 2d 14h 53m to empty |
| Remain Capacity/Energy | 90.6 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 91.1 % | State Of Health | 99.5 % |
| Temperature | 20.9 °C | Cycle | 43 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-09 23:59 |
| Voltage | 53.19 V | Cell (MIN/MAX) | 3.323 V / 3.325 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.47 A (-78 W) | Runtime | 2d 13h 1m to empty |
| Remain Capacity/Energy | 89.9 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.4 % | State Of Health | 99.5 % |
| Temperature | 22.1 °C | Cycle | 45 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-09 23:58 |
| Voltage | 53.14 V | Cell (MIN/MAX) | 3.320 V / 3.321 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.56 A (-83 W) | Runtime | 2d 9h 3m to empty |
| Remain Capacity/Energy | 89.3 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 89.8 % | State Of Health | 99.5 % |
| Temperature | 22.9 °C | Cycle | 46 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-09 23:58 |
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.45 A (-76 W) | Runtime | 2d 14h 11m to empty |
| Remain Capacity/Energy | 89.9 Ah (4.6 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 90.6 % | State Of Health | 99.2 % |
| Temperature | 21.4 °C | Cycle | 45 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-09 23:58 |