Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.544 kW
12/15/2025 13:06 (2028 days) Production Consumption NET Usage
Now 0.748 kW 0.204 kW -0.544 kW
Today 5.248 kWh (0.400 kW) 5.921 kWh (0.451 kW) 0.673 kWh (0.051 kW)
  - This Week 5.548 kWh (3.585 kWh/day) 22.911 kWh (14.805 kWh/day) 17.363 kWh (11.220 kWh/day)
  - This Month 126.299 kWh (8.682 kWh/day) 284.184 kWh (19.536 kWh/day) 157.885 kWh (10.854 kWh/day)
  - This Year 5.995 MWh (17.201 kWh/day) 7.200 MWh (20.659 kWh/day) 1.205 MWh (3.458 kWh/day)
Yesterday 0.300 kWh (0.012 kW) 16.990 kWh (0.708 kW) 16.690 kWh (0.695 kW)
Last 7 Days 59.809 kWh (8.545 kWh/day) 178.180 kWh (25.456 kWh/day) 118.371 kWh (16.912 kWh/day)
Last 30 Days 266.149 kWh (8.872 kWh/day) 560.724 kWh (18.691 kWh/day) 294.575 kWh (9.819 kWh/day)
Last One Year 6.101 MWh (16.715 kWh/day) 7.574 MWh (20.751 kWh/day) 1.473 MWh (4.036 kWh/day)
Lifetime Since PTO 35.446 MWh (17.473 kW/day) 39.153 MWh (19.301 kW/day) 3.707 MWh (1.827 kW/day)
Lifetime Since Install 35.480 MWh 39.733 MWh 4.253 MWh
Voltage/Current 248.2 V / 3.0 A 248.0 V / 0.8 A 248.1 V / -2.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 08/24/2025 23:58 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 24.623 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.314 2.078 10.730 0.000 kW
1.273 kWh
0.000 kW
7.640 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.251 1.977 10.186
03 - 202224****** IQ7+M [5] VCOP 0.000 0.267 1.306 2.068 10.619
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.347 2.128 10.836
05 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.182 1.893 9.815
06 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.241 1.983 10.288
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.266 1.201 2.023 10.212 0.000 kW
1.249 kWh
0.000 kW
6.243 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.255 2.039 10.287
09 - 202217****** IQ7+ [5] VCOP 0.000 0.281 1.257 2.023 10.235
10 - 202244****** IQ7+M [5] VCOP 0.000 0.263 1.260 2.065 10.428
11 - 202224****** IQ7+M [5] VCOP 0.000 0.264 1.269 2.111 10.658
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.261 1.262 1.756 9.183 0.000 kW
1.307 kWh
0.000 kW
5.228 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.269 1.293 1.760 9.272
14 - 202216****** IQ7+ [5] VCOP 0.000 0.270 1.332 1.825 9.609
15 - 202245****** IQ7+M [5] VCOP 0.000 0.269 1.340 1.829 9.635
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.756 kWh
0.230 kW
5.511 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.511 5.484 38.440
Panel Layout Each Group Production

Charger History
Voltage PV 0.43 V Voltage Charge 52.82 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.5 °C / 28.9 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-24 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.10 V Current/Power -6.22 A (-0.330 kW)
Remain Capacity/Energy 416.6 Ah (21.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 70.2 % State Of Health 98.9 %
Run Time 2d 18h 58m to empty Report Date 2025-08-24 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack