Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.029 kW
06/27/2026 15:51 (2222 days) Production Consumption NET Usage
Now 0.384 kW 0.355 kW -0.029 kW
Today 8.519 kWh (0.536 kW) 8.038 kWh (0.506 kW) -0.481 kWh (-0.030 kW)
  - This Week 132.682 kWh (19.919 kWh/day) 146.924 kWh (22.057 kWh/day) 14.242 kWh (2.138 kWh/day)
  - This Month 792.328 kWh (29.717 kWh/day) 633.780 kWh (23.771 kWh/day) -158.548 kWh (-5.947 kWh/day)
  - This Year 3.527 MWh (19.851 kWh/day) 3.204 MWh (18.033 kWh/day) -0.323 MWh (-1.818 kWh/day)
Yesterday 18.889 kWh (0.787 kW) 17.732 kWh (0.739 kW) -1.157 kWh (-0.048 kW)
Last 7 Days 140.216 kWh (20.031 kWh/day) 157.891 kWh (22.556 kWh/day) 17.675 kWh (2.525 kWh/day)
Last 30 Days (05/28/2026) 897.915 kWh (29.930 kWh/day) 714.745 kWh (23.825 kWh/day) -183.170 kWh (-6.106 kWh/day)
Last One Year 6.692 MWh (18.335 kWh/day) 7.735 MWh (21.192 kWh/day) 1.043 MWh (2.857 kWh/day)
Lifetime Since PTO 39.092 MWh (17.588 kW/day) 42.714 MWh (19.218 kW/day) 3.622 MWh (1.630 kW/day)
Lifetime Since Install 39.126 MWh 43.294 MWh 4.168 MWh
Voltage/Current 250.3 V / 1.5 A 250.3 V / 1.4 A 250.3 V / -0.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/17/2023 23:33 (14.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.282 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.919 1.197 11.260 0.000 kW
1.829 kWh
0.000 kW
10.977 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.793 1.114 10.484
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.841 1.132 10.755
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.856 1.152 10.946
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.710 1.008 9.791
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.858 1.150 10.790
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.732 1.025 10.121 0.000 kW
1.742 kWh
0.000 kW
8.709 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.742 1.025 9.998
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.744 1.038 10.159
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.735 1.037 10.226
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.757 1.044 10.408
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.289 1.764 1.230 10.661 0.000 kW
1.810 kWh
0.000 kW
7.238 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.292 1.792 1.264 10.781
14 - 202216****** IQ7+ [5] VCOP 0.000 0.292 1.842 1.310 11.255
15 - 202245****** IQ7+M [5] VCOP 0.000 0.281 1.841 1.315 11.281
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.453 kWh
0.000 kW
1.358 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.358 1.369 11.286
Panel Layout Each Group Production

Battery History
Voltage 52.63 V Current/Power -98.54 A (-5.187 kW)
Remain Capacity/Energy 383.7 Ah (19.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 63.9 % State Of Health 100.0 %
Run Time 3h 53m to empty Report Date 2023-06-17 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.