Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.393 kW
06/27/2026 22:16 (2222 days) Production Consumption NET Usage
Now 0.000 kW 0.393 kW 0.393 kW
Today 10.018 kWh (0.449 kW) 15.686 kWh (0.703 kW) 5.668 kWh (0.254 kW)
  - This Week 134.181 kWh (19.367 kWh/day) 154.572 kWh (22.310 kWh/day) 20.391 kWh (2.943 kWh/day)
  - This Month 793.827 kWh (29.478 kWh/day) 641.428 kWh (23.819 kWh/day) -152.399 kWh (-5.659 kWh/day)
  - This Year 3.528 MWh (19.829 kWh/day) 3.211 MWh (18.049 kWh/day) -0.317 MWh (-1.781 kWh/day)
Yesterday 18.889 kWh (0.787 kW) 17.732 kWh (0.739 kW) -1.157 kWh (-0.048 kW)
Last 7 Days 134.181 kWh (19.169 kWh/day) 155.304 kWh (22.186 kWh/day) 21.123 kWh (3.018 kWh/day)
Last 30 Days (05/28/2026) 892.153 kWh (29.738 kWh/day) 716.082 kWh (23.869 kWh/day) -176.071 kWh (-5.869 kWh/day)
Last One Year 6.692 MWh (18.334 kWh/day) 7.736 MWh (21.195 kWh/day) 1.044 MWh (2.861 kWh/day)
Lifetime Since PTO 39.094 MWh (17.587 kW/day) 42.722 MWh (19.219 kW/day) 3.628 MWh (1.632 kW/day)
Lifetime Since Install 39.128 MWh 43.302 MWh 4.174 MWh
Voltage/Current 250.8 V / 0.0 A 250.7 V / 1.6 A 250.8 V / 1.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/09/2026 23:11 (11.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.218 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.270 1.827 0.756 4.169 0.000 kW
1.773 kWh
0.000 kW
10.636 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.259 1.743 0.717 3.960
03 - 202224****** IQ7+M [0] ---- 0.000 0.268 1.807 0.753 4.177
04 - 202232****** IQ7+ [0] ---- 0.000 0.271 1.800 0.735 4.038
05 - 202244****** IQ7+M [0] ---- 0.000 0.261 1.713 0.711 3.886
06 - 202245****** IQ7+M [0] ---- 0.000 0.265 1.746 0.731 4.012
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.820 0.734 4.194 0.000 kW
1.969 kWh
0.000 kW
9.844 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.981 0.747 4.325
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.991 0.750 4.330
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.017 0.750 4.346
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.034 0.754 4.344
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.184 1.160 0.633 3.246 0.000 kW
1.220 kWh
0.000 kW
4.878 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.187 1.211 0.660 3.412
14 - 202216****** IQ7+ [0] ---- 0.000 0.190 1.255 0.678 3.560
15 - 202245****** IQ7+M [0] ---- 0.000 0.190 1.252 0.682 3.577
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 23.284 0.000 kW
0.287 kWh
0.000 kW
0.860 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.158 0.860 0.284 1.460
Panel Layout Each Group Production

Charger History
Voltage PV 0.57 V Voltage Charge 52.58 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 24.0 °C / 20.4 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-03-09 23:58
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.