Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 7.868 kW
09/13/2025 21:38 (1935 days) Production Consumption NET Usage
Now 0.000 kW 7.868 kW 7.868 kW
Today 22.447 kWh (1.037 kW) 22.458 kWh (1.037 kW) 0.011 kWh (0.001 kW)
  - This Week 148.841 kWh (21.565 kWh/day) 107.122 kWh (15.520 kWh/day) -41.719 kWh (-6.044 kWh/day)
  - This Month 285.769 kWh (22.150 kWh/day) 302.847 kWh (23.473 kWh/day) 17.078 kWh (1.324 kWh/day)
  - This Year 4.793 MWh (18.730 kWh/day) 5.474 MWh (21.389 kWh/day) 0.680 MWh (2.659 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.689 kW/day) 37.426 MWh (19.332 kW/day) 3.182 MWh (1.643 kW/day)
Lifetime Since Install 34.278 MWh 38.006 MWh 3.728 MWh
Voltage/Current 248.6 V / 0.0 A 248.7 V / 31.6 A 248.7 V / 31.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/19/2022 21:38 (11.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.540 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.286 1.116 1.712 11.210 0.000 kW
1.081 kWh
0.000 kW
6.488 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.282 1.068 1.636 10.763
03 - 202224****** IQ7+M [0] ---- 0.000 0.287 1.113 1.718 11.227
04 - 202232****** IQ7+ [0] ---- 0.000 0.286 1.079 1.666 10.980
05 - 202244****** IQ7+M [0] ---- 0.000 0.285 1.071 1.651 10.775
06 - 202245****** IQ7+M [0] ---- 0.000 0.282 1.041 1.610 10.487
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.291 0.932 1.708 10.988 0.000 kW
1.022 kWh
0.000 kW
5.108 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.056 1.782 11.504
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.037 1.789 11.343
10 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.038 1.801 11.512
11 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.045 1.799 11.548
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.198 0.994 1.302 8.983 0.000 kW
0.986 kWh
0.000 kW
3.944 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.198 0.996 1.291 8.874
14 - 202216****** IQ7+ [0] ---- 0.000 0.199 0.982 1.300 9.037
15 - 202245****** IQ7+M [0] ---- 0.000 0.196 0.973 1.280 8.803
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -4.61 A (-0.245 kW)
Remain Capacity/Energy 494.4 Ah (25.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.4 % State Of Health 100.0 %
Run Time 4d 11h 14m to empty Report Date 2022-09-19 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.