Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.157 kW
03/23/2026 16:53 (2126 days) Production Consumption NET Usage
Now 0.462 kW 0.305 kW -0.157 kW
Today 9.680 kWh (0.572 kW) 9.236 kWh (0.546 kW) -0.444 kWh (-0.026 kW)
  - This Week 32.428 kWh (19.031 kWh/day) 21.542 kWh (12.643 kWh/day) -10.886 kWh (-6.389 kWh/day)
  - This Month 406.415 kWh (17.901 kWh/day) 358.561 kWh (15.793 kWh/day) -47.854 kWh (-2.108 kWh/day)
  - This Year 1.040 MWh (12.733 kWh/day) 1.458 MWh (17.850 kWh/day) 0.418 MWh (5.117 kWh/day)
Yesterday 22.748 kWh (0.949 kW) 12.306 kWh (0.513 kW) -10.442 kWh (-0.435 kW)
Last 7 Days 154.659 kWh (22.094 kWh/day) 133.254 kWh (19.036 kWh/day) -21.405 kWh (-3.058 kWh/day)
Last 30 Days (02/21/2026) 488.087 kWh (16.270 kWh/day) 459.551 kWh (15.318 kWh/day) -28.536 kWh (-0.951 kWh/day)
Last One Year 6.065 MWh (16.616 kWh/day) 7.893 MWh (21.625 kWh/day) 1.828 MWh (5.009 kWh/day)
Lifetime Since PTO 36.606 MWh (17.213 kW/day) 40.969 MWh (19.264 kW/day) 4.363 MWh (2.052 kW/day)
Lifetime Since Install 36.640 MWh 41.549 MWh 4.909 MWh
Voltage/Current 250.6 V / 1.8 A 250.6 V / 1.2 A 250.6 V / -0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/31/2023 22:45 (13.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.094 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.202 2.193 9.834 0.000 kW
1.169 kWh
0.000 kW
7.016 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.139 2.128 9.425
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.196 2.194 9.803
04 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.200 2.193 9.826
05 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.126 2.053 9.135
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.153 2.078 9.281
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.205 2.103 9.327 0.000 kW
1.221 kWh
0.000 kW
6.105 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.219 2.209 9.852
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.205 2.173 9.774
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 1.233 2.259 9.984
11 - 202224****** IQ7+M [5] VCOP 0.000 0.303 1.242 2.282 10.076
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.218 0.928 1.673 7.706 0.000 kW
0.986 kWh
0.000 kW
3.946 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.225 0.956 1.694 7.930
14 - 202216****** IQ7+ [5] VCOP 0.000 0.232 1.031 1.785 8.320
15 - 202245****** IQ7+M [5] VCOP 0.000 0.236 1.031 1.773 8.290
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.514 kWh
0.000 kW
3.028 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.237 3.028 2.883 22.005
Panel Layout Each Group Production

Battery History
Voltage 52.70 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 337.5 Ah (17.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 56.3 % State Of Health 100.0 %
Run Time 9d 9h 0m to empty Report Date 2023-03-31 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.