Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.268 kW
06/27/2026 07:14 (2222 days) Production Consumption NET Usage
Now 0.312 kW 0.044 kW -0.268 kW
Today 0.258 kWh (0.036 kW) 0.724 kWh (0.100 kW) 0.466 kWh (0.064 kW)
  - This Week 124.421 kWh (19.744 kWh/day) 139.610 kWh (22.154 kWh/day) 15.189 kWh (2.410 kWh/day)
  - This Month 784.067 kWh (29.809 kWh/day) 626.466 kWh (23.817 kWh/day) -157.601 kWh (-5.992 kWh/day)
  - This Year 3.518 MWh (19.845 kWh/day) 3.196 MWh (18.028 kWh/day) -0.322 MWh (-1.816 kWh/day)
Yesterday 18.889 kWh (0.787 kW) 17.732 kWh (0.739 kW) -1.157 kWh (-0.048 kW)
Last 7 Days 156.834 kWh (22.405 kWh/day) 156.023 kWh (22.289 kWh/day) -0.811 kWh (-0.116 kWh/day)
Last 30 Days (05/28/2026) 912.587 kWh (30.420 kWh/day) 712.921 kWh (23.764 kWh/day) -199.666 kWh (-6.656 kWh/day)
Last One Year 6.694 MWh (18.339 kWh/day) 7.731 MWh (21.182 kWh/day) 1.038 MWh (2.843 kWh/day)
Lifetime Since PTO 39.084 MWh (17.587 kW/day) 42.707 MWh (19.218 kW/day) 3.623 MWh (1.630 kW/day)
Lifetime Since Install 39.118 MWh 43.287 MWh 4.169 MWh
Voltage/Current 248.8 V / 1.3 A 248.7 V / 0.2 A 248.8 V / -1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/16/2023 23:37 (13.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.742 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.176 0.526 1.342 11.143 0.000 kW
0.510 kWh
0.000 kW
3.058 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.166 0.497 1.283 10.507
03 - 202224****** IQ7+M [5] VCOP 0.000 0.172 0.519 1.321 10.763
04 - 202232****** IQ7+ [5] VCOP 0.000 0.175 0.522 1.335 10.924
05 - 202244****** IQ7+M [5] VCOP 0.000 0.167 0.487 1.242 9.952
06 - 202245****** IQ7+M [5] VCOP 0.000 0.171 0.507 1.305 10.798
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.159 0.468 1.220 10.192 0.000 kW
0.473 kWh
0.000 kW
2.364 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.161 0.473 1.229 10.067
09 - 202217****** IQ7+ [5] VCOP 0.000 0.165 0.474 1.226 10.134
10 - 202244****** IQ7+M [5] VCOP 0.000 0.163 0.474 1.224 10.202
11 - 202224****** IQ7+M [5] VCOP 0.000 0.162 0.475 1.235 10.339
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.162 0.477 1.269 10.314 0.000 kW
0.508 kWh
0.000 kW
2.031 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.169 0.495 1.304 10.443
14 - 202216****** IQ7+ [5] VCOP 0.000 0.172 0.529 1.340 10.838
15 - 202245****** IQ7+M [5] VCOP 0.000 0.168 0.531 1.348 10.874
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.430 kWh
0.000 kW
1.289 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.289 1.138 8.438
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.