| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.100 kW | |||
|---|---|---|---|
| 06/27/2026 05:50 (2222 days) | Production | Consumption | NET Usage |
| Now | 0.053 kW | -0.047 kW | -0.100 kW |
| Today | 0.011 kWh (0.002 kW) | 0.728 kWh (0.124 kW) | 0.717 kWh (0.122 kW) |
| - This Week | 124.174 kWh (19.888 kWh/day) | 139.614 kWh (22.361 kWh/day) | 15.440 kWh (2.473 kWh/day) |
| - This Month | 783.820 kWh (29.866 kWh/day) | 626.470 kWh (23.870 kWh/day) | -157.350 kWh (-5.996 kWh/day) |
| - This Year | 3.518 MWh (19.850 kWh/day) | 3.196 MWh (18.034 kWh/day) | -0.322 MWh (-1.816 kWh/day) |
| Yesterday | 18.889 kWh (0.787 kW) | 17.732 kWh (0.739 kW) | -1.157 kWh (-0.048 kW) |
| Last 7 Days | 157.112 kWh (22.445 kWh/day) | 156.091 kWh (22.299 kWh/day) | -1.021 kWh (-0.146 kWh/day) |
| Last 30 Days (05/28/2026) | 913.250 kWh (30.442 kWh/day) | 711.996 kWh (23.733 kWh/day) | -201.254 kWh (-6.708 kWh/day) |
| Last One Year | 6.694 MWh (18.339 kWh/day) | 7.732 MWh (21.184 kWh/day) | 1.039 MWh (2.846 kWh/day) |
| Lifetime Since PTO | 39.084 MWh (17.588 kW/day) | 42.707 MWh (19.218 kW/day) | 3.623 MWh (1.630 kW/day) |
| Lifetime Since Install | 39.118 MWh | 43.287 MWh | 4.169 MWh |
| Voltage/Current | 250.5 V / 0.2 A | 250.4 V / -0.2 A | 250.4 V / -0.4 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 08/04/2023 23:20 (13.8 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 11.850 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.188 | 0.757 | 1.544 | 13.651 | 0.000 kW 0.732 kWh |
0.000 kW 4.394 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.172 | 0.717 | 1.453 | 12.796 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.181 | 0.750 | 1.507 | 13.158 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.187 | 0.750 | 1.536 | 13.435 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.181 | 0.689 | 1.378 | 11.970 | |||
| 06 - 202245****** | IQ7+M | [5] VC-- | 0.000 | 0.182 | 0.730 | 1.489 | 13.141 | |||
| front | 07 - 202206****** | IQ7+ | [5] VC-- | 0.000 | 0.187 | 0.676 | 1.400 | 12.679 | 0.000 kW 0.682 kWh |
0.000 kW 3.411 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.177 | 0.678 | 1.401 | 12.355 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.181 | 0.680 | 1.410 | 12.482 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.180 | 0.685 | 1.420 | 12.702 | |||
| 11 - 202224****** | IQ7+M | [5] VC-- | 0.000 | 0.182 | 0.692 | 1.437 | 12.919 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.184 | 0.690 | 1.442 | 12.602 | 0.000 kW 0.728 kWh |
0.000 kW 2.911 kWh |
| 13 - 202223****** | IQ7+ | [5] VC-- | 0.000 | 0.188 | 0.721 | 1.478 | 12.479 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.197 | 0.748 | 1.528 | 13.084 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.192 | 0.752 | 1.539 | 13.117 | |||
| wind | 16 - 202320****** | IQ7XS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.378 kWh |
0.000 kW 1.134 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.230 | 1.134 | 1.351 | 9.540 | |||
|
||||||||||