Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.485 kW
07/01/2025 07:28 (1861 days) Production Consumption NET Usage
Now 0.370 kW 4.855 kW 4.485 kW
Today 0.140 kWh (0.019 kW) 5.753 kWh (0.768 kW) 5.613 kWh (0.749 kW)
  - This Week 57.426 kWh (24.845 kWh/day) 73.435 kWh (31.771 kWh/day) 16.009 kWh (6.926 kWh/day)
  - This Month 0.140 kWh (0.449 kWh/day) 5.753 kWh (18.431 kWh/day) 5.613 kWh (17.983 kWh/day)
  - This Year 3.030 MWh (16.711 kWh/day) 3.133 MWh (17.280 kWh/day) 0.103 MWh (0.569 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.450 kW/day) 35.085 MWh (18.850 kW/day) 2.604 MWh (1.399 kW/day)
Lifetime Since Install 32.515 MWh 35.665 MWh 3.150 MWh
Voltage/Current 247.8 V / 1.5 A 247.8 V / 19.6 A 247.8 V / 18.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/23/2022 22:54 (10.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.052 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.083 0.286 1.306 8.076 0.000 kW
0.278 kWh
0.000 kW
1.667 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.081 0.270 1.257 7.614
03 - 202224****** IQ7+M [5] VCOP 0.000 0.084 0.295 1.338 8.009
04 - 202232****** IQ7+ [5] VCOP 0.000 0.084 0.280 1.296 7.727
05 - 202244****** IQ7+M [5] VCOP 0.000 0.080 0.270 1.316 7.889
06 - 202245****** IQ7+M [5] VCOP 0.000 0.081 0.266 1.273 7.693
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.078 0.258 1.309 8.186 0.000 kW
0.256 kWh
0.000 kW
1.279 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.077 0.258 1.451 8.785
09 - 202217****** IQ7+ [5] VCOP 0.000 0.078 0.256 1.525 9.060
10 - 202244****** IQ7+M [5] VCOP 0.000 0.079 0.257 1.519 9.118
11 - 202224****** IQ7+M [5] VCOP 0.000 0.078 0.250 1.489 9.036
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.075 0.277 0.805 5.166 0.000 kW
0.277 kWh
0.000 kW
1.106 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.076 0.278 0.852 5.388
14 - 202216****** IQ7+ [5] VCOP 0.000 0.077 0.285 0.853 5.407
15 - 202245****** IQ7+M [5] VCOP 0.000 0.076 0.267 0.821 5.225
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.60 V Current/Power -1.35 A (-71 W)
Remain Capacity/Energy 287.4 Ah (14.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 47.9 % State Of Health 100.0 %
Run Time 8d 20h 53m to empty Report Date 2022-10-23 23:57
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.