Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.257 kW
10/17/2025 05:16 (1969 days) Production Consumption NET Usage
Now 0.000 kW 0.257 kW 0.257 kW
Today 0.000 kWh (0.000 kW) 1.800 kWh (0.341 kW) 1.800 kWh (0.341 kW)
  - This Week 54.442 kWh (10.430 kWh/day) 70.623 kWh (13.530 kWh/day) 16.181 kWh (3.100 kWh/day)
  - This Month 271.331 kWh (16.729 kWh/day) 279.391 kWh (17.226 kWh/day) 8.060 kWh (0.497 kWh/day)
  - This Year 5.371 MWh (18.569 kWh/day) 6.134 MWh (21.210 kWh/day) 0.764 MWh (2.641 kWh/day)
Yesterday 22.469 kWh (0.936 kW) 13.268 kWh (0.553 kW) -9.201 kWh (-0.383 kW)
Last 7 Days 78.066 kWh (11.153 kWh/day) 95.710 kWh (13.673 kWh/day) 17.644 kWh (2.521 kWh/day)
Last 30 Days 516.566 kWh (17.219 kWh/day) 569.978 kWh (18.999 kWh/day) 53.412 kWh (1.780 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.390 MWh (20.245 kWh/day) 1.114 MWh (3.053 kWh/day)
Lifetime Since PTO 34.821 MWh (17.683 kW/day) 38.086 MWh (19.341 kW/day) 3.265 MWh (1.658 kW/day)
Lifetime Since Install 34.855 MWh 38.666 MWh 3.811 MWh
Voltage/Current 254.9 V / 0.0 A 255.0 V / 1.0 A 255.0 V / 1.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/19/2023 23:43 (10.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.053 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.225 0.781 1.609 7.169 0.000 kW
0.753 kWh
0.000 kW
4.519 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.221 0.748 1.545 6.844
03 - 202224****** IQ7+M [0] ---- 0.000 0.187 0.765 1.595 7.076
04 - 202232****** IQ7+ [0] ---- 0.000 0.225 0.763 1.559 6.928
05 - 202244****** IQ7+M [0] ---- 0.000 0.179 0.732 1.572 6.969
06 - 202245****** IQ7+M [0] ---- 0.000 0.174 0.731 1.533 6.826
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.239 0.776 1.666 7.218 0.000 kW
0.778 kWh
0.000 kW
3.891 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.249 0.772 1.817 7.803
09 - 202217****** IQ7+ [0] ---- 0.000 0.207 0.781 1.878 8.060
10 - 202244****** IQ7+M [0] ---- 0.000 0.248 0.790 1.895 8.095
11 - 202224****** IQ7+M [0] ---- 0.000 0.206 0.773 1.852 7.908
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.140 0.659 0.876 4.308 0.000 kW
0.661 kWh
0.000 kW
2.643 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.145 0.660 0.925 4.538
14 - 202216****** IQ7+ [0] ---- 0.000 0.148 0.665 0.939 4.565
15 - 202245****** IQ7+M [0] ---- 0.000 0.147 0.659 0.917 4.450
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.69 V Current/Power -1.35 A (-71 W)
Remain Capacity/Energy 270.6 Ah (13.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 45.1 % State Of Health 100.0 %
Run Time 8d 8h 26m to empty Report Date 2023-02-19 23:57
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.