Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 9.307 kW
01/12/2025 21:35 (1691 days) Production Consumption NET Usage
Now 0.000 kW 9.307 kW 9.307 kW
Today 12.543 kWh (0.581 kW) 44.906 kWh (2.080 kW) 32.363 kWh (1.499 kW)
  - This Week 12.543 kWh (13.941 kWh/day) 44.906 kWh (49.910 kWh/day) 32.363 kWh (35.970 kWh/day)
  - This Month 117.280 kWh (9.856 kWh/day) 305.896 kWh (25.706 kWh/day) 188.616 kWh (15.850 kWh/day)
  - This Year 0.117 MWh (9.856 kWh/day) 0.306 MWh (25.706 kWh/day) 0.189 MWh (15.850 kWh/day)
Yesterday 3.752 kWh (0.156 kW) 21.675 kWh (0.902 kW) 17.923 kWh (0.746 kW)
Last 7 Days 71.618 kWh (10.230 kWh/day) 155.217 kWh (22.172 kWh/day) 83.599 kWh (11.942 kWh/day)
Last 30 Days 243.564 kWh (8.119 kWh/day) 672.733 kWh (22.424 kWh/day) 429.169 kWh (14.305 kWh/day)
Last One Year 6.725 MWh (18.424 kWh/day) 6.310 MWh (17.286 kWh/day) -0.415 MWh (-1.138 kWh/day)
Lifetime Since PTO 29.568 MWh (17.476 kW/day) 32.259 MWh (19.066 kW/day) 2.690 MWh (1.590 kW/day)
Lifetime Since Install 29.602 MWh 32.839 MWh 3.237 MWh
Voltage/Current 249.0 V / 0.0 A 249.0 V / 37.4 A 249.0 V / 37.4 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 06/10/2022 22:10 (14.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.259 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.297 2.108 1.862 14.265 0.000 kW
1.980 kWh
0.000 kW
11.878 kWh
02 - 202244177619 IQ7+M V--- 0.000 0.296 1.976 1.744 13.425
03 - 202224101754 IQ7+M ---- 0.000 0.297 1.995 1.789 13.727
04 - 202232127100 IQ7+ ---- 0.000 0.296 1.997 1.756 13.611
05 - 202244171601 IQ7+M ---- 0.000 0.296 1.788 1.668 12.731
06 - 202245013024 IQ7+M V--- 0.000 0.296 2.015 1.775 13.549
front 07 - 202206091803 IQ7+ ---- 0.000 0.296 1.879 1.662 12.889 0.000 kW
1.877 kWh
0.000 kW
9.385 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.296 1.879 1.590 12.431
09 - 202217001404 IQ7+ ---- 0.000 0.296 1.865 1.603 12.526
10 - 202244165234 IQ7+M ---- 0.000 0.297 1.873 1.663 12.891
11 - 202224104308 IQ7+M ---- 0.000 0.296 1.888 1.705 13.074
back 12 - 202211186551 IQ7+ ---- 0.000 0.292 2.275 1.788 14.069 0.000 kW
2.249 kWh
0.000 kW
8.996 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.293 2.220 1.721 13.569
14 - 202216155993 IQ7+ ---- 0.000 0.294 2.276 1.795 14.150
15 - 202245015670 IQ7+M ---- 0.000 0.289 2.226 1.771 13.919
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.18 V Current/Power -2.31 A (-0.123 kW)
Remain Capacity/Energy 496.2 Ah (25.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.7 % State Of Health 100.0 %
Run Time 8d 22h 48m to empty Report Date 2022-06-10 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.14 V Cell (MIN/MAX) 3.316 V / 3.325 V (0.009 V)
Current/Power -1.16 A (-61 W) Runtime 5d 22h 27m to empty
Remain Capacity/Energy 165.4 Ah (8.5 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 82.7 % State Of Health 100.0 %
Temperature 23.0 °C Cycle 67
MOSFET CFET = ON, DFET = ON Reported 2022-06-10 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.316 V 3.317 V 3.318 V 3.318 V 3.319 V 3.319 V 3.320 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.321 V 3.323 V 3.323 V 3.324 V 3.324 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.18 V Cell (MIN/MAX) 3.323 V / 3.323 V (0.000 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 94.4 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 94.4 % State Of Health 100.0 %
Temperature 22.6 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-10 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
pack temperature
Voltage 53.21 V Cell (MIN/MAX) 3.325 V / 3.326 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 93.7 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.7 % State Of Health 100.0 %
Temperature 23.7 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-10 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.326 V 3.326 V 3.325 V 3.326 V 3.325 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.325 V 3.326 V 3.326 V 3.325 V 3.325 V 3.326 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.16 V Cell (MIN/MAX) 3.321 V / 3.323 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 93.5 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.5 % State Of Health 100.0 %
Temperature 23.9 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-10 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.323 V 3.322 V 3.322 V 3.322 V 3.322 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.322 V 3.323 V 3.322 V 3.323 V 3.322 V 3.323 V 3.321 V
pack voltage and current cell voltages
pack temperature
Voltage 53.18 V Cell (MIN/MAX) 3.323 V / 3.323 V (0.000 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 93.7 Ah (4.8 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 94.0 % State Of Health 99.7 %
Temperature 22.6 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-06-10 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
pack temperature