Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.383 kW
09/23/2024 15:21 (1580 days) Production Consumption NET Usage
Now 1.344 kW -0.039 kW -1.383 kW
Today 8.359 kWh (0.543 kW) 3.599 kWh (0.234 kW) -4.760 kWh (-0.309 kW)
  - This Week 31.962 kWh (19.488 kWh/day) 7.922 kWh (4.830 kWh/day) -24.040 kWh (-14.658 kWh/day)
  - This Month 545.333 kWh (24.086 kWh/day) 288.203 kWh (12.729 kWh/day) -257.130 kWh (-11.357 kWh/day)
  - This Year 5.444 MWh (20.415 kWh/day) 4.731 MWh (17.744 kWh/day) -0.712 MWh (-2.671 kWh/day)
Yesterday 23.603 kWh (0.984 kW) 4.323 kWh (0.180 kW) -19.280 kWh (-0.804 kW)
Last 7 Days 138.980 kWh (19.855 kWh/day) 57.375 kWh (8.197 kWh/day) -81.605 kWh (-11.658 kWh/day)
Last 30 Days 697.992 kWh (23.267 kWh/day) 403.024 kWh (13.434 kWh/day) -294.968 kWh (-9.833 kWh/day)
Last One Year 6.577 MWh (18.018 kWh/day) 6.501 MWh (17.810 kWh/day) -0.076 MWh (-0.209 kWh/day)
Lifetime Since PTO 28.166 MWh (17.820 kW/day) 30.411 MWh (19.239 kW/day) 2.244 MWh (1.420 kW/day)
Lifetime Since Install 28.200 MWh 30.991 MWh 2.790 MWh
Voltage/Current 249.8 V / 5.4 A 249.8 V / -0.2 A 249.8 V / -5.5 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 03/05/2022 23:59 (11.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.578 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.195 1.170 1.930 10.773 0.000 kW
1.135 kWh
0.000 kW
6.810 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.191 1.097 1.819 10.160
03 - 202224101754 IQ7+M VCOP 0.000 0.196 1.172 1.918 10.570
04 - 202232127100 IQ7+ VCOP 0.000 0.197 1.147 1.877 10.281
05 - 202244171601 IQ7+M VCOP 0.000 0.193 1.120 1.865 10.428
06 - 202245013024 IQ7+M VCOP 0.000 0.191 1.103 1.790 9.992
front 07 - 202206091803 IQ7+ VCOP 0.000 0.221 1.121 1.866 8.821 0.000 kW
1.186 kWh
0.000 kW
5.931 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.229 1.184 2.034 9.180
09 - 202217001404 IQ7+ VCOP 0.000 0.220 1.209 2.037 9.095
10 - 202244165234 IQ7+M VCOP 0.000 0.223 1.213 2.073 10.246
11 - 202224104308 IQ7+M VCOP 0.000 0.221 1.204 2.097 9.516
back 12 - 202211186551 IQ7+ VCOP 0.000 0.161 0.952 1.217 6.727 0.000 kW
0.959 kWh
0.000 kW
3.837 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.161 0.952 1.222 6.789
14 - 202216155993 IQ7+ VCOP 0.000 0.163 0.972 1.258 6.956
15 - 202245015670 IQ7+M VCOP 0.000 0.162 0.961 1.236 6.823
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.69 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 205.9 Ah (10.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 34.3 % State Of Health 100.0 %
Run Time 4d 18h 25m to empty Report Date 2022-03-05 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.71 V Cell (MIN/MAX) 3.287 V / 3.301 V (0.014 V)
Current/Power -0.47 A (-25 W) Runtime 6d 0h 31m to empty
Remain Capacity/Energy 68.7 Ah (3.5 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 34.3 % State Of Health 100.0 %
Temperature 18.0 °C Cycle 56
MOSFET CFET = ON, DFET = OFF Reported 2022-03-05 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.287 V 3.289 V 3.289 V 3.290 V 3.291 V 3.291 V 3.292 V 3.293 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.294 V 3.295 V 3.296 V 3.298 V 3.299 V 3.300 V 3.301 V 3.301 V
pack voltage and current cell voltages
pack temperature
Voltage 52.67 V Cell (MIN/MAX) 3.291 V / 3.292 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 57.6 Ah (2.9 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 57.6 % State Of Health 100.0 %
Temperature 21.0 °C Cycle 11
MOSFET CFET = ON, DFET = ON Reported 2022-03-05 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.291 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V
pack voltage and current cell voltages
pack temperature
Voltage 52.70 V Cell (MIN/MAX) 3.293 V / 3.294 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 62.6 Ah (3.2 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 62.6 % State Of Health 100.0 %
Temperature 19.0 °C Cycle 10
MOSFET CFET = ON, DFET = ON Reported 2022-03-05 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.293 V 3.294 V 3.293 V 3.293 V 3.294 V 3.293 V 3.293 V 3.293 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V
pack voltage and current cell voltages
pack temperature
Voltage 52.68 V Cell (MIN/MAX) 3.292 V / 3.293 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 63.9 Ah (3.3 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 63.9 % State Of Health 100.0 %
Temperature 17.9 °C Cycle 10
MOSFET CFET = ON, DFET = ON Reported 2022-03-05 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.293 V 3.293 V 3.292 V 3.293 V 3.293 V 3.292 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.293 V 3.293 V 3.292 V 3.292 V 3.293 V 3.293 V 3.293 V
pack voltage and current cell voltages
pack temperature
Voltage 52.67 V Cell (MIN/MAX) 3.290 V / 3.292 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 61.5 Ah (3.2 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 61.7 % State Of Health 99.7 %
Temperature 20.2 °C Cycle 11
MOSFET CFET = ON, DFET = ON Reported 2022-03-05 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.290 V 3.292 V 3.292 V 3.292 V 3.291 V 3.292 V 3.291 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.292 V 3.292 V 3.291 V 3.291 V 3.292 V 3.291 V 3.292 V
pack voltage and current cell voltages
pack temperature