Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.568 kW
05/12/2026 18:41 (2176 days) Production Consumption NET Usage
Now 1.191 kW 0.623 kW -0.568 kW
Today 39.935 kWh (2.136 kW) 9.242 kWh (0.494 kW) -30.693 kWh (-1.642 kW)
  - This Week 79.780 kWh (28.705 kWh/day) 34.003 kWh (12.234 kWh/day) -45.777 kWh (-16.471 kWh/day)
  - This Month 297.855 kWh (25.287 kWh/day) 151.140 kWh (12.831 kWh/day) -146.715 kWh (-12.456 kWh/day)
  - This Year 2.251 MWh (17.081 kWh/day) 2.211 MWh (16.777 kWh/day) -0.040 MWh (-0.304 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 152.808 kWh (21.830 kWh/day) 109.747 kWh (15.678 kWh/day) -43.061 kWh (-6.152 kWh/day)
Last 30 Days (04/12/2026) 708.144 kWh (23.605 kWh/day) 439.212 kWh (14.640 kWh/day) -268.932 kWh (-8.964 kWh/day)
Last One Year 6.297 MWh (17.252 kWh/day) 7.795 MWh (21.356 kWh/day) 1.498 MWh (4.105 kWh/day)
Lifetime Since PTO 37.817 MWh (17.373 kW/day) 41.722 MWh (19.167 kW/day) 3.905 MWh (1.794 kW/day)
Lifetime Since Install 37.850 MWh 42.302 MWh 4.451 MWh
Voltage/Current 249.6 V / 4.8 A 249.4 V / 2.5 A 249.5 V / -2.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/26/2023 23:04 (10.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.489 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 1.265 1.265 6.642 0.000 kW
1.236 kWh
0.000 kW
7.418 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.211 1.207 1.210 6.329
03 - 202224****** IQ7+M [5] VCOP 0.000 0.217 1.243 1.252 6.555
04 - 202232****** IQ7+ [5] VCOP 0.000 0.222 1.242 1.248 6.559
05 - 202244****** IQ7+M [5] VCOP 0.000 0.212 1.221 1.219 6.346
06 - 202245****** IQ7+M [5] VCOP 0.000 0.215 1.241 1.236 6.476
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.257 1.265 1.234 6.487 0.000 kW
1.417 kWh
0.000 kW
7.083 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.258 1.409 1.373 7.066
09 - 202217****** IQ7+ [5] VCOP 0.000 0.256 1.486 1.442 7.494
10 - 202244****** IQ7+M [5] VCOP 0.000 0.253 1.466 1.428 7.380
11 - 202224****** IQ7+M [5] VCOP 0.000 0.259 1.457 1.419 7.337
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.126 0.682 0.701 4.101 0.000 kW
0.747 kWh
0.000 kW
2.987 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.131 0.752 0.771 4.421
14 - 202216****** IQ7+ [5] VCOP 0.000 0.133 0.780 0.801 4.607
15 - 202245****** IQ7+M [5] VCOP 0.000 0.133 0.774 0.798 4.601
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.38 A (-73 W)
Remain Capacity/Energy 524.1 Ah (26.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 88.4 % State Of Health 98.9 %
Run Time 15d 19h 46m to empty Report Date 2023-10-26 23:55
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.