Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.278 kW
03/20/2026 13:09 (2123 days) Production Consumption NET Usage
Now 3.509 kW 0.231 kW -3.278 kW
Today 11.293 kWh (0.858 kW) 5.749 kWh (0.437 kW) -5.544 kWh (-0.421 kW)
  - This Week 105.096 kWh (18.943 kWh/day) 111.020 kWh (20.011 kWh/day) 5.924 kWh (1.068 kWh/day)
  - This Month 339.817 kWh (17.384 kWh/day) 315.047 kWh (16.117 kWh/day) -24.770 kWh (-1.267 kWh/day)
  - This Year 0.974 MWh (12.397 kWh/day) 1.415 MWh (18.013 kWh/day) 0.441 MWh (5.616 kWh/day)
Yesterday 13.403 kWh (0.558 kW) 14.863 kWh (0.619 kW) 1.460 kWh (0.061 kW)
Last 7 Days 147.881 kWh (21.126 kWh/day) 133.492 kWh (19.070 kWh/day) -14.389 kWh (-2.056 kWh/day)
Last 30 Days (02/18/2026) 444.728 kWh (14.824 kWh/day) 500.573 kWh (16.686 kWh/day) 55.845 kWh (1.861 kWh/day)
Last One Year 6.082 MWh (16.664 kWh/day) 7.887 MWh (21.609 kWh/day) 1.805 MWh (4.945 kWh/day)
Lifetime Since PTO 36.539 MWh (17.207 kW/day) 40.926 MWh (19.272 kW/day) 4.386 MWh (2.066 kW/day)
Lifetime Since Install 36.573 MWh 41.506 MWh 4.932 MWh
Voltage/Current 252.7 V / 13.9 A 252.7 V / 0.9 A 252.7 V / -13.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/05/2023 23:42 (12.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.616 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.562 1.394 12.056 0.000 kW
1.511 kWh
0.000 kW
9.063 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.253 1.489 1.316 11.459
03 - 202224****** IQ7+M [5] VCOP 0.000 0.264 1.551 1.360 11.909
04 - 202232****** IQ7+ [5] VCOP 0.000 0.268 1.570 1.366 12.063
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.425 1.318 11.149
06 - 202245****** IQ7+M [5] VCOP 0.000 0.262 1.465 1.359 11.507
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.279 1.459 1.407 11.831 0.000 kW
1.520 kWh
0.000 kW
7.602 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.281 1.537 1.409 11.974
09 - 202217****** IQ7+ [5] VCOP 0.000 0.278 1.528 1.383 11.803
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.529 1.423 12.051
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.551 1.446 12.300
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.207 1.356 1.023 9.639 0.000 kW
1.396 kWh
0.000 kW
5.584 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.213 1.383 1.027 9.720
14 - 202216****** IQ7+ [5] VCOP 0.000 0.215 1.422 1.079 10.104
15 - 202245****** IQ7+M [5] VCOP 0.000 0.214 1.424 1.078 10.106
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.683 kWh
0.000 kW
1.366 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.366 1.347 14.127
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.