Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.942 kW
05/13/2026 14:04 (2177 days) Production Consumption NET Usage
Now 1.370 kW 0.428 kW -0.942 kW
Today 18.568 kWh (1.317 kW) 6.889 kWh (0.489 kW) -11.679 kWh (-0.828 kW)
  - This Week 100.363 kWh (27.982 kWh/day) 43.808 kWh (12.214 kWh/day) -56.555 kWh (-15.768 kWh/day)
  - This Month 318.438 kWh (25.300 kWh/day) 160.945 kWh (12.787 kWh/day) -157.493 kWh (-12.513 kWh/day)
  - This Year 2.271 MWh (17.132 kWh/day) 2.221 MWh (16.749 kWh/day) -0.051 MWh (-0.383 kWh/day)
Yesterday 41.950 kWh (1.750 kW) 12.158 kWh (0.507 kW) -29.792 kWh (-1.243 kW)
Last 7 Days 166.371 kWh (23.767 kWh/day) 123.543 kWh (17.649 kWh/day) -42.828 kWh (-6.118 kWh/day)
Last 30 Days (04/13/2026) 713.153 kWh (23.772 kWh/day) 436.589 kWh (14.553 kWh/day) -276.564 kWh (-9.219 kWh/day)
Last One Year 6.310 MWh (17.288 kWh/day) 7.793 MWh (21.350 kWh/day) 1.483 MWh (4.062 kWh/day)
Lifetime Since PTO 37.837 MWh (17.376 kW/day) 41.731 MWh (19.164 kW/day) 3.894 MWh (1.788 kW/day)
Lifetime Since Install 37.871 MWh 42.311 MWh 4.440 MWh
Voltage/Current 248.8 V / 5.5 A 249.0 V / 1.7 A 248.9 V / -3.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/13/2023 23:09 (20.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.923 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.199 0.978 1.012 3.907 0.000 kW
0.960 kWh
0.000 kW
5.760 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.190 0.934 0.969 3.708
03 - 202224****** IQ7+M [5] VCOP 0.000 0.197 0.972 1.012 3.888
04 - 202232****** IQ7+ [5] VCOP 0.000 0.194 0.982 1.021 3.902
05 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.944 0.979 3.714
06 - 202245****** IQ7+M [5] VCOP 0.000 0.194 0.951 0.984 3.767
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.258 1.047 1.070 4.040 0.000 kW
1.191 kWh
0.000 kW
5.953 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.258 1.197 1.236 4.488
09 - 202217****** IQ7+ [5] VCOP 0.000 0.258 1.287 1.327 4.669
10 - 202244****** IQ7+M [5] VCOP 0.000 0.255 1.249 1.291 4.589
11 - 202224****** IQ7+M [5] VCOP 0.000 0.258 1.174 1.208 4.388
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.066 0.278 0.281 1.760 0.000 kW
0.346 kWh
0.000 kW
1.385 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.089 0.355 0.362 2.035
14 - 202216****** IQ7+ [5] VCOP 0.000 0.093 0.379 0.385 2.166
15 - 202245****** IQ7+M [5] VCOP 0.000 0.092 0.373 0.378 2.137
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.412 kWh
0.000 kW
4.824 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.230 4.824 0.833 0.919
Panel Layout Each Group Production

Battery History
Voltage 53.23 V Current/Power -0.66 A (-35 W)
Remain Capacity/Energy 454.5 Ah (23.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 76.6 % State Of Health 98.9 %
Run Time 28d 16h 38m to empty Report Date 2023-12-13 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.