Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.407 kW
07/01/2025 04:26 (1861 days) Production Consumption NET Usage
Now 0.000 kW 0.407 kW 0.407 kW
Today 0.000 kWh (0.000 kW) 3.597 kWh (0.807 kW) 3.597 kWh (0.807 kW)
  - This Week 57.286 kWh (26.217 kWh/day) 71.279 kWh (32.621 kWh/day) 13.993 kWh (6.404 kWh/day)
  - This Month 0.000 kWh (0.000 kWh/day) 3.597 kWh (19.356 kWh/day) 3.597 kWh (19.356 kWh/day)
  - This Year 3.030 MWh (16.722 kWh/day) 3.131 MWh (17.280 kWh/day) 0.101 MWh (0.558 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.452 kW/day) 35.083 MWh (18.850 kW/day) 2.602 MWh (1.398 kW/day)
Lifetime Since Install 32.515 MWh 35.663 MWh 3.148 MWh
Voltage/Current 251.4 V / 0.0 A 251.4 V / 1.6 A 251.4 V / 1.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/02/2023 23:20 (9.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.207 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.236 1.241 1.119 4.742 0.000 kW
1.211 kWh
0.000 kW
7.266 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.231 1.181 1.093 4.554
03 - 202224****** IQ7+M [0] ---- 0.000 0.237 1.241 1.122 4.701
04 - 202232****** IQ7+ [0] ---- 0.000 0.236 1.216 1.118 4.669
05 - 202244****** IQ7+M [0] ---- 0.000 0.235 1.201 1.124 4.617
06 - 202245****** IQ7+M [0] ---- 0.000 0.228 1.186 1.113 4.597
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.294 1.376 1.356 4.764 0.000 kW
1.482 kWh
0.000 kW
7.408 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.503 1.455 5.265
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.536 1.544 5.572
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.521 1.515 5.529
11 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.472 1.486 5.338
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.146 0.573 0.445 2.903 0.000 kW
0.633 kWh
0.000 kW
2.533 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.145 0.653 0.518 3.045
14 - 202216****** IQ7+ [0] ---- 0.000 0.147 0.661 0.509 3.048
15 - 202245****** IQ7+M [0] ---- 0.000 0.145 0.646 0.504 2.971
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.24 V Current/Power -6.19 A (-0.330 kW)
Remain Capacity/Energy 480.9 Ah (24.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 80.2 % State Of Health 100.0 %
Run Time 3d 5h 41m to empty Report Date 2023-02-02 23:58
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.