Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.223 kW
09/13/2025 10:28 (1935 days) Production Consumption NET Usage
Now 2.639 kW 0.416 kW -2.223 kW
Today 3.598 kWh (0.343 kW) 4.809 kWh (0.459 kW) 1.211 kWh (0.116 kW)
  - This Week 129.992 kWh (20.195 kWh/day) 89.473 kWh (13.900 kWh/day) -40.519 kWh (-6.295 kWh/day)
  - This Month 266.920 kWh (21.462 kWh/day) 285.198 kWh (22.932 kWh/day) 18.278 kWh (1.470 kWh/day)
  - This Year 4.774 MWh (18.691 kWh/day) 5.456 MWh (21.359 kWh/day) 0.682 MWh (2.669 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.225 MWh (17.683 kW/day) 37.408 MWh (19.328 kW/day) 3.183 MWh (1.644 kW/day)
Lifetime Since Install 34.259 MWh 37.988 MWh 3.729 MWh
Voltage/Current 253.3 V / 10.4 A 253.2 V / 1.6 A 253.3 V / -8.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/26/2023 23:53 (13.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.805 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 1.630 1.505 12.014 0.000 kW
1.596 kWh
0.000 kW
9.574 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.570 1.414 11.465
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.621 1.474 11.864
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.631 1.504 12.026
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.532 1.292 11.082
06 - 202245****** IQ7+M [5] VCOP 0.000 0.302 1.589 1.406 11.558
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.300 1.633 1.362 11.641 0.000 kW
1.621 kWh
0.000 kW
8.105 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 1.584 1.329 11.536
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.592 1.335 11.519
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.635 1.389 11.708
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.661 1.427 11.933
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 1.334 1.488 10.342 0.000 kW
1.386 kWh
0.000 kW
5.544 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 1.346 1.514 10.554
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 1.431 1.574 10.948
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.434 1.574 10.929
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.234 1.582 1.580 11.597 0.000 kW
1.582 kWh
0.000 kW
1.582 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.75 V Current/Power -1.29 A (-68 W)
Remain Capacity/Energy 292.2 Ah (15.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 48.7 % State Of Health 100.0 %
Run Time 9d 10h 30m to empty Report Date 2023-04-26 23:56
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.