Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.109 kW
09/23/2024 09:31 (1580 days) Production Consumption NET Usage
Now 1.266 kW 0.157 kW -1.109 kW
Today 1.155 kWh (0.121 kW) 3.258 kWh (0.341 kW) 2.103 kWh (0.220 kW)
  - This Week 24.758 kWh (17.725 kWh/day) 7.581 kWh (5.427 kWh/day) -17.177 kWh (-12.298 kWh/day)
  - This Month 538.129 kWh (24.026 kWh/day) 287.862 kWh (12.852 kWh/day) -250.267 kWh (-11.174 kWh/day)
  - This Year 5.436 MWh (20.407 kWh/day) 4.731 MWh (17.759 kWh/day) -0.705 MWh (-2.648 kWh/day)
Yesterday 23.603 kWh (0.984 kW) 4.323 kWh (0.180 kW) -19.280 kWh (-0.804 kW)
Last 7 Days 138.980 kWh (19.855 kWh/day) 57.375 kWh (8.197 kWh/day) -81.605 kWh (-11.658 kWh/day)
Last 30 Days 697.992 kWh (23.267 kWh/day) 403.024 kWh (13.434 kWh/day) -294.968 kWh (-9.833 kWh/day)
Last One Year 6.577 MWh (18.018 kWh/day) 6.501 MWh (17.810 kWh/day) -0.076 MWh (-0.209 kWh/day)
Lifetime Since PTO 28.159 MWh (17.818 kW/day) 30.410 MWh (19.242 kW/day) 2.251 MWh (1.424 kW/day)
Lifetime Since Install 28.193 MWh 30.990 MWh 2.797 MWh
Voltage/Current 249.5 V / 5.1 A 249.6 V / 0.6 A 249.5 V / -4.4 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 05/31/2022 22:51 (14.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.235 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.289 2.088 2.100 12.017 0.000 kW
1.974 kWh
0.000 kW
11.841 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.281 1.965 1.955 11.358
03 - 202224101754 IQ7+M VCOP 0.000 0.286 1.992 2.012 11.781
04 - 202232127100 IQ7+ VCOP 0.000 0.285 1.995 1.993 11.619
05 - 202244171601 IQ7+M VCOP 0.000 0.283 1.812 1.825 11.063
06 - 202245013024 IQ7+M VCOP 0.000 0.277 1.988 2.003 11.496
front 07 - 202206091803 IQ7+ VCOP 0.000 0.295 1.847 1.897 11.018 0.000 kW
1.841 kWh
0.000 kW
9.203 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.291 1.801 1.827 10.718
09 - 202217001404 IQ7+ VCOP 0.000 0.292 1.812 1.850 10.792
10 - 202244165234 IQ7+M VCOP 0.000 0.293 1.865 1.922 11.069
11 - 202224104308 IQ7+M VCOP 0.000 0.292 1.878 1.925 11.186
back 12 - 202211186551 IQ7+ VCOP 0.000 0.255 2.073 2.102 11.823 0.000 kW
2.048 kWh
0.000 kW
8.191 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.254 2.015 2.018 11.539
14 - 202216155993 IQ7+ VCOP 0.000 0.254 2.068 2.108 11.948
15 - 202245015670 IQ7+M VCOP 0.000 0.249 2.034 2.076 11.816
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.26 A (-67 W)
Remain Capacity/Energy 525.0 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Run Time 17d 8h 40m to empty Report Date 2022-05-31 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.17 V Cell (MIN/MAX) 3.317 V / 3.327 V (0.010 V)
Current/Power -0.42 A (-22 W) Runtime 17d 7h 40m to empty
Remain Capacity/Energy 175.0 Ah (9.0 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Temperature 22.5 °C Cycle 66
MOSFET CFET = ON, DFET = ON Reported 2022-05-31 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.319 V 3.319 V 3.320 V 3.321 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.324 V 3.325 V 3.326 V 3.327 V 3.327 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.4 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.4 % State Of Health 100.0 %
Temperature 22.0 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-31 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.324 V 3.325 V 3.325 V 3.324 V 3.325 V 3.325 V 3.323 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.325 V 3.324 V 3.323 V 3.325 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.23 V Cell (MIN/MAX) 3.325 V / 3.327 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.4 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.4 % State Of Health 100.0 %
Temperature 23.3 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-31 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.327 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage 53.18 V Cell (MIN/MAX) 3.323 V / 3.324 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.4 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.4 % State Of Health 100.0 %
Temperature 23.5 °C Cycle 18
MOSFET CFET = ON, DFET = ON Reported 2022-05-31 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.324 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
pack temperature
Voltage 53.19 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.1 Ah (5.1 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 99.4 % State Of Health 99.7 %
Temperature 22.1 °C Cycle 19
MOSFET CFET = ON, DFET = ON Reported 2022-05-31 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.324 V 3.324 V 3.324 V 3.324 V 3.323 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.323 V 3.324 V 3.325 V 3.325 V 3.324 V 3.324 V
pack voltage and current cell voltages
pack temperature