Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.291 kW
07/01/2025 06:31 (1861 days) Production Consumption NET Usage
Now 0.023 kW 0.314 kW 0.291 kW
Today 0.015 kWh (0.002 kW) 5.037 kWh (0.768 kW) 5.022 kWh (0.766 kW)
  - This Week 57.301 kWh (25.216 kWh/day) 72.719 kWh (32.001 kWh/day) 15.418 kWh (6.785 kWh/day)
  - This Month 0.015 kWh (0.055 kWh/day) 5.037 kWh (18.440 kWh/day) 5.022 kWh (18.385 kWh/day)
  - This Year 3.030 MWh (16.714 kWh/day) 3.132 MWh (17.279 kWh/day) 0.103 MWh (0.566 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.451 kW/day) 35.084 MWh (18.850 kW/day) 2.604 MWh (1.399 kW/day)
Lifetime Since Install 32.515 MWh 35.664 MWh 3.150 MWh
Voltage/Current 249.8 V / 0.1 A 249.8 V / 1.3 A 249.8 V / 1.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/03/2023 23:50 (13.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.921 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.298 1.972 2.237 10.989 0.000 kW
1.925 kWh
0.000 kW
11.548 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.287 1.898 2.169 10.562
03 - 202224****** IQ7+M [5] VC-- 0.000 0.299 1.989 2.234 10.965
04 - 202232****** IQ7+ [5] VC-- 0.000 0.300 2.013 2.237 11.002
05 - 202244****** IQ7+M [5] VC-- 0.000 0.290 1.828 2.091 10.260
06 - 202245****** IQ7+M [5] VC-- 0.000 0.293 1.848 2.123 10.425
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.301 1.846 2.163 10.599 0.000 kW
1.947 kWh
0.000 kW
9.735 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.300 1.964 2.228 11.059
09 - 202217****** IQ7+ [5] VC-- 0.000 0.300 1.965 2.190 10.913
10 - 202244****** IQ7+M [5] VC-- 0.000 0.300 1.972 2.282 11.223
11 - 202224****** IQ7+M [5] VC-- 0.000 0.300 1.987 2.310 11.329
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.228 1.625 1.698 8.518 0.000 kW
1.695 kWh
0.000 kW
6.779 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.234 1.670 1.714 8.709
14 - 202216****** IQ7+ [5] VCOP 0.000 0.238 1.742 1.803 9.182
15 - 202245****** IQ7+M [5] VCOP 0.000 0.241 1.743 1.793 9.154
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.234 2.859 0.952 18.797 0.000 kW
2.859 kWh
0.000 kW
2.859 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.16 V Current/Power -4.50 A (-0.239 kW)
Remain Capacity/Energy 443.7 Ah (22.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 74.0 % State Of Health 100.0 %
Run Time 4d 2h 36m to empty Report Date 2023-04-03 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.