Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.788 kW
09/23/2024 09:21 (1580 days) Production Consumption NET Usage
Now 0.973 kW 0.185 kW -0.788 kW
Today 0.961 kWh (0.103 kW) 3.233 kWh (0.345 kW) 2.272 kWh (0.242 kW)
  - This Week 24.564 kWh (17.677 kWh/day) 7.556 kWh (5.437 kWh/day) -17.008 kWh (-12.239 kWh/day)
  - This Month 537.935 kWh (24.025 kWh/day) 287.837 kWh (12.855 kWh/day) -250.098 kWh (-11.170 kWh/day)
  - This Year 5.436 MWh (20.407 kWh/day) 4.731 MWh (17.760 kWh/day) -0.705 MWh (-2.647 kWh/day)
Yesterday 23.603 kWh (0.984 kW) 4.323 kWh (0.180 kW) -19.280 kWh (-0.804 kW)
Last 7 Days 138.980 kWh (19.855 kWh/day) 57.375 kWh (8.197 kWh/day) -81.605 kWh (-11.658 kWh/day)
Last 30 Days 697.992 kWh (23.267 kWh/day) 403.024 kWh (13.434 kWh/day) -294.968 kWh (-9.833 kWh/day)
Last One Year 6.577 MWh (18.018 kWh/day) 6.501 MWh (17.810 kWh/day) -0.076 MWh (-0.209 kWh/day)
Lifetime Since PTO 28.159 MWh (17.818 kW/day) 30.410 MWh (19.242 kW/day) 2.251 MWh (1.425 kW/day)
Lifetime Since Install 28.193 MWh 30.990 MWh 2.797 MWh
Voltage/Current 249.4 V / 3.9 A 249.4 V / 0.7 A 249.4 V / -3.2 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 07/02/2022 23:05 (14.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.346 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.291 1.794 2.129 14.022 0.000 kW
1.759 kWh
0.000 kW
10.556 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.291 1.736 2.007 13.164
03 - 202224101754 IQ7+M VCOP 0.000 0.290 1.779 2.049 13.406
04 - 202232127100 IQ7+ VCOP 0.000 0.291 1.772 2.044 13.307
05 - 202244171601 IQ7+M VCOP 0.000 0.291 1.729 1.870 12.164
06 - 202245013024 IQ7+M VCOP 0.000 0.290 1.746 2.016 13.328
front 07 - 202206091803 IQ7+ VCOP 0.000 0.289 1.698 1.929 12.470 0.000 kW
1.676 kWh
0.000 kW
8.378 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.289 1.610 1.904 12.091
09 - 202217001404 IQ7+ VCOP 0.000 0.290 1.631 1.909 12.245
10 - 202244165234 IQ7+M VCOP 0.000 0.290 1.704 1.938 12.606
11 - 202224104308 IQ7+M VCOP 0.000 0.290 1.735 1.942 12.665
back 12 - 202211186551 IQ7+ VCOP 0.000 0.288 1.624 2.184 14.168 0.000 kW
1.603 kWh
0.000 kW
6.411 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.287 1.552 2.112 13.616
14 - 202216155993 IQ7+ VCOP 0.000 0.288 1.631 2.175 14.141
15 - 202245015670 IQ7+M VCOP 0.000 0.287 1.604 2.133 13.872
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.26 A (-67 W)
Remain Capacity/Energy 525.6 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.6 % State Of Health 100.0 %
Run Time 17d 9h 8m to empty Report Date 2022-07-02 23:51
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.45 A (-24 W) Runtime 16d 4h 28m to empty
Remain Capacity/Energy 175.2 Ah (9.0 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 87.6 % State Of Health 100.0 %
Temperature 25.0 °C Cycle 69
MOSFET CFET = ON, DFET = ON Reported 2022-07-02 23:51
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.323 V 3.323 V 3.324 V 3.325 V 3.326 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.328 V 3.328 V 3.329 V 3.330 V 3.331 V 3.331 V 3.330 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.324 V / 3.325 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 24.0 °C Cycle 20
MOSFET CFET = ON, DFET = ON Reported 2022-07-02 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.324 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.324 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.324 V 3.325 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage 53.23 V Cell (MIN/MAX) 3.326 V / 3.328 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 25.5 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-07-02 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.328 V 3.327 V 3.326 V 3.327 V 3.326 V 3.327 V 3.327 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.327 V 3.327 V 3.327 V 3.327 V 3.326 V 3.326 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage 53.18 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 25.8 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-07-02 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.324 V 3.323 V 3.323 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.323 V 3.323 V 3.324 V 3.323 V 3.323 V 3.323 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.323 V / 3.325 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.2 Ah (5.1 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.7 %
Temperature 24.2 °C Cycle 21
MOSFET CFET = ON, DFET = ON Reported 2022-07-02 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.325 V 3.325 V 3.325 V 3.324 V 3.324 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.325 V 3.324 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
pack voltage and current cell voltages
pack temperature