Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.226 kW
02/19/2026 14:51 (2094 days) Production Consumption NET Usage
Now 0.655 kW 0.429 kW -0.226 kW
Today 7.857 kWh (0.529 kW) 7.908 kWh (0.532 kW) 0.051 kWh (0.003 kW)
  - This Week 50.484 kWh (10.928 kWh/day) 59.482 kWh (12.876 kWh/day) 8.998 kWh (1.948 kWh/day)
  - This Month 293.228 kWh (15.748 kWh/day) 347.054 kWh (18.639 kWh/day) 53.826 kWh (2.891 kWh/day)
  - This Year 0.539 MWh (10.856 kWh/day) 0.930 MWh (18.747 kWh/day) 0.392 MWh (7.892 kWh/day)
Yesterday 3.293 kWh (0.137 kW) 14.590 kWh (0.608 kW) 11.297 kWh (0.471 kW)
Last 7 Days 89.820 kWh (12.831 kWh/day) 134.108 kWh (19.158 kWh/day) 44.288 kWh (6.327 kWh/day)
Last 30 Days 373.460 kWh (12.449 kWh/day) 576.414 kWh (19.214 kWh/day) 202.954 kWh (6.765 kWh/day)
Last One Year 6.181 MWh (16.964 kWh/day) 7.634 MWh (20.950 kWh/day) 1.452 MWh (3.986 kWh/day)
Lifetime Since PTO 36.104 MWh (17.236 kW/day) 40.442 MWh (19.307 kW/day) 4.337 MWh (2.071 kW/day)
Lifetime Since Install 36.138 MWh 41.022 MWh 4.883 MWh
Voltage/Current 249.8 V / 2.6 A 249.8 V / 1.7 A 249.8 V / -0.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/31/2024 23:21 (9.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.754 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.039 0.197 0.172 1.449 0.000 kW
0.186 kWh
0.000 kW
1.116 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.034 0.179 0.156 1.334
03 - 202224****** IQ7+M [5] VCOP 0.000 0.037 0.194 0.170 1.435
04 - 202232****** IQ7+ [5] VCOP 0.000 0.039 0.192 0.168 1.420
05 - 202244****** IQ7+M [5] VCOP 0.000 0.034 0.174 0.152 1.302
06 - 202245****** IQ7+M [5] VCOP 0.000 0.037 0.181 0.157 1.348
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.033 0.175 0.153 1.297 0.000 kW
0.177 kWh
0.000 kW
0.884 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.036 0.179 0.156 1.324
09 - 202217****** IQ7+ [5] VCOP 0.000 0.033 0.176 0.154 1.306
10 - 202244****** IQ7+M [5] VCOP 0.000 0.034 0.176 0.155 1.312
11 - 202224****** IQ7+M [5] VCOP 0.000 0.034 0.178 0.156 1.325
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.033 0.171 0.150 1.267 0.000 kW
0.188 kWh
0.000 kW
0.754 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.036 0.187 0.165 1.369
14 - 202216****** IQ7+ [5] VCOP 0.000 0.037 0.198 0.175 1.450
15 - 202245****** IQ7+M [5] VCOP 0.000 0.037 0.198 0.175 1.445
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.13 V Current/Power -0.96 A (-51 W)
Remain Capacity/Energy 387.0 Ah (19.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.3 % State Of Health 98.9 %
Run Time 16d 19h 7m to empty Report Date 2024-01-31 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.