Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.824 kW
07/10/2025 21:05 (1870 days) Production Consumption NET Usage
Now 0.000 kW 0.824 kW 0.824 kW
Today 16.102 kWh (0.762 kW) 25.685 kWh (1.216 kW) 9.583 kWh (0.454 kW)
  - This Week 115.697 kWh (23.707 kWh/day) 217.762 kWh (44.620 kWh/day) 102.065 kWh (20.914 kWh/day)
  - This Month 245.406 kWh (24.839 kWh/day) 386.488 kWh (39.118 kWh/day) 141.082 kWh (14.280 kWh/day)
  - This Year 3.275 MWh (17.158 kWh/day) 3.514 MWh (18.408 kWh/day) 0.239 MWh (1.250 kWh/day)
Yesterday 25.046 kWh (1.044 kW) 40.411 kWh (1.684 kW) 15.365 kWh (0.640 kW)
Last 7 Days 187.533 kWh (26.791 kWh/day) 299.677 kWh (42.813 kWh/day) 112.144 kWh (16.021 kWh/day)
Last 30 Days 652.855 kWh (21.763 kWh/day) 970.553 kWh (32.353 kWh/day) 317.698 kWh (10.590 kWh/day)
Last One Year 6.296 MWh (17.249 kWh/day) 6.482 MWh (17.760 kWh/day) 0.186 MWh (0.511 kWh/day)
Lifetime Since PTO 32.726 MWh (17.492 kW/day) 35.466 MWh (18.957 kW/day) 2.740 MWh (1.464 kW/day)
Lifetime Since Install 32.760 MWh 36.046 MWh 3.286 MWh
Voltage/Current 249.2 V / 0.0 A 249.3 V / 3.3 A 249.2 V / 3.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/06/2023 23:40 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.141 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.279 2.237 2.140 11.985 0.000 kW
2.131 kWh
0.000 kW
12.785 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.268 2.096 1.990 11.301
03 - 202224****** IQ7+M [0] ---- 0.000 0.277 2.141 2.020 11.595
04 - 202232****** IQ7+ [0] ---- 0.000 0.283 2.200 2.071 11.757
05 - 202244****** IQ7+M [0] ---- 0.000 0.270 1.940 1.797 10.596
06 - 202245****** IQ7+M [0] ---- 0.000 0.275 2.172 2.061 11.603
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.279 2.047 1.893 10.872 0.000 kW
2.031 kWh
0.000 kW
10.154 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.278 1.961 1.893 10.748
09 - 202217****** IQ7+ [0] ---- 0.000 0.278 2.007 1.880 10.832
10 - 202244****** IQ7+M [0] ---- 0.000 0.275 2.045 1.881 10.904
11 - 202224****** IQ7+M [0] ---- 0.000 0.281 2.094 1.923 11.070
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.251 2.082 2.026 11.183 0.000 kW
2.127 kWh
0.000 kW
8.507 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.257 2.066 2.039 11.404
14 - 202216****** IQ7+ [0] ---- 0.000 0.259 2.173 2.104 11.755
15 - 202245****** IQ7+M [0] ---- 0.000 0.262 2.185 2.113 11.792
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.695 1.135 8.033 0.000 kW
1.695 kWh
0.000 kW
1.695 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -5.22 A (-0.278 kW)
Remain Capacity/Energy 492.3 Ah (25.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 83.0 % State Of Health 98.9 %
Run Time 3d 22h 18m to empty Report Date 2023-07-06 23:55
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.