Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.358 kW
06/30/2025 17:36 (1860 days) Production Consumption NET Usage
Now 2.046 kW 0.688 kW -1.358 kW
Today 26.245 kWh (1.490 kW) 19.329 kWh (1.097 kW) -6.916 kWh (-0.393 kW)
  - This Week 56.203 kWh (32.420 kWh/day) 56.348 kWh (32.503 kWh/day) 0.145 kWh (0.084 kWh/day)
  - This Month 627.492 kWh (21.104 kWh/day) 761.982 kWh (25.627 kWh/day) 134.490 kWh (4.523 kWh/day)
  - This Year 3.029 MWh (16.757 kWh/day) 3.116 MWh (17.240 kWh/day) 0.087 MWh (0.483 kWh/day)
Yesterday 29.958 kWh (1.249 kW) 37.019 kWh (1.543 kW) 7.061 kWh (0.294 kW)
Last 7 Days 164.939 kWh (23.565 kWh/day) 274.127 kWh (39.165 kWh/day) 109.188 kWh (15.600 kWh/day)
Last 30 Days 617.926 kWh (20.598 kWh/day) 775.650 kWh (25.855 kWh/day) 157.724 kWh (5.257 kWh/day)
Last One Year 6.346 MWh (17.387 kWh/day) 6.392 MWh (17.513 kWh/day) 0.046 MWh (0.126 kWh/day)
Lifetime Since PTO 32.480 MWh (17.455 kW/day) 35.068 MWh (18.846 kW/day) 2.588 MWh (1.391 kW/day)
Lifetime Since Install 32.513 MWh 35.648 MWh 3.134 MWh
Voltage/Current 249.1 V / 8.2 A 249.2 V / 2.8 A 249.1 V / -5.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/19/2025 23:44 (12.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.404 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.274 1.305 1.925 8.700 0.000 kW
1.272 kWh
0.000 kW
7.634 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.239 1.829 8.360
03 - 202224****** IQ7+M [5] VCOP 0.000 0.272 1.289 1.919 8.265
04 - 202232****** IQ7+ [5] VCOP 0.000 0.269 1.297 1.975 8.918
05 - 202244****** IQ7+M [5] VCOP 0.000 0.262 1.236 1.732 8.457
06 - 202245****** IQ7+M [5] VCOP 0.000 0.270 1.268 1.817 8.567
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.285 1.302 1.758 8.890 0.000 kW
1.309 kWh
0.000 kW
6.546 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.306 1.825 8.671
09 - 202217****** IQ7+ [5] VCOP 0.000 0.283 1.303 1.820 8.698
10 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.309 1.825 8.718
11 - 202224****** IQ7+M [5] VCOP 0.000 0.280 1.326 1.846 9.030
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.226 1.026 1.801 7.874 0.000 kW
1.056 kWh
0.000 kW
4.224 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.046 1.843 8.177
14 - 202216****** IQ7+ [5] VCOP 0.000 0.232 1.077 1.881 8.367
15 - 202245****** IQ7+M [5] VCOP 0.000 0.231 1.076 1.885 8.363
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.48 V Voltage Charge 52.13 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.6 °C / 25.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-04-19 23:58
voltage in/out power and energy

Battery History
Voltage 52.39 V Current/Power -11.30 A (-0.592 kW)
Remain Capacity/Energy 275.2 Ah (14.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 46.4 % State Of Health 98.9 %
Run Time 1d 0h 21m to empty Report Date 2025-04-19 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.