Date Offset  [+30][+10][+05][+01][-01][-05]

Importing from grid by 0.313 kW
03/16/2026 17:44 (2119 days) Production Consumption NET Usage
Now 0.086 kW 0.399 kW 0.313 kW
Today 5.193 kWh (0.293 kW) 9.084 kWh (0.512 kW) 3.891 kWh (0.219 kW)
  - This Week 17.082 kWh (9.820 kWh/day) 21.958 kWh (12.624 kWh/day) 4.876 kWh (2.803 kWh/day)
  - This Month 251.803 kWh (15.998 kWh/day) 225.985 kWh (14.358 kWh/day) -25.818 kWh (-1.640 kWh/day)
  - This Year 0.886 MWh (11.851 kWh/day) 1.326 MWh (17.739 kWh/day) 0.440 MWh (5.888 kWh/day)
Yesterday 11.889 kWh (0.495 kW) 12.874 kWh (0.537 kW) 0.985 kWh (0.041 kW)
Last 7 Days 122.495 kWh (17.499 kWh/day) 97.961 kWh (13.994 kWh/day) -24.534 kWh (-3.505 kWh/day)
Last 30 Days (02/14/2026) 392.453 kWh (13.082 kWh/day) 450.621 kWh (15.021 kWh/day) 58.168 kWh (1.939 kWh/day)
Last One Year 6.050 MWh (16.576 kWh/day) 7.836 MWh (21.468 kWh/day) 1.786 MWh (4.892 kWh/day)
Lifetime Since PTO 36.451 MWh (17.196 kW/day) 40.837 MWh (19.265 kW/day) 4.385 MWh (2.069 kW/day)
Lifetime Since Install 36.485 MWh 41.417 MWh 4.931 MWh
Voltage/Current 251.1 V / 0.3 A 251.1 V / 1.6 A 251.1 V / 1.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/09/2026 23:11 (11.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.218 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.270 1.827 0.756 4.169 0.000 kW
1.773 kWh
0.000 kW
10.636 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.259 1.743 0.717 3.960
03 - 202224****** IQ7+M [5] VCOP 0.000 0.268 1.807 0.753 4.177
04 - 202232****** IQ7+ [5] VCOP 0.000 0.271 1.800 0.735 4.038
05 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.713 0.711 3.886
06 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.746 0.731 4.012
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.820 0.734 4.194 0.000 kW
1.969 kWh
0.000 kW
9.844 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.981 0.747 4.325
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.991 0.750 4.330
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.017 0.750 4.346
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.034 0.754 4.344
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.184 1.160 0.633 3.246 0.000 kW
1.220 kWh
0.000 kW
4.878 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.187 1.211 0.660 3.412
14 - 202216****** IQ7+ [5] VCOP 0.000 0.190 1.255 0.678 3.560
15 - 202245****** IQ7+M [5] VC-- 0.000 0.190 1.252 0.682 3.577
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 23.284 0.000 kW
0.430 kWh
0.000 kW
0.860 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.158 0.860 0.284 1.460
Panel Layout Each Group Production

Charger History
Voltage PV 0.57 V Voltage Charge 52.58 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 24.0 °C / 20.4 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-03-09 23:58
voltage in/out power and energy

Battery History
Voltage 52.73 V Current/Power -1.23 A (-64 W)
Remain Capacity/Energy 245.1 Ah (12.5 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 44.7 % State Of Health 91.4 %
Run Time 8d 7h 16m to empty Report Date 2026-03-09 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.