Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.703 kW
07/04/2026 16:22 (2229 days) Production Consumption NET Usage
Now 3.397 kW 2.694 kW -0.703 kW
Today 27.310 kWh (1.666 kW) 25.228 kWh (1.539 kW) -2.082 kWh (-0.127 kW)
  - This Week 203.262 kWh (30.419 kWh/day) 227.145 kWh (33.993 kWh/day) 23.883 kWh (3.574 kWh/day)
  - This Month 121.661 kWh (33.035 kWh/day) 153.005 kWh (41.546 kWh/day) 31.344 kWh (8.511 kWh/day)
  - This Year 3.731 MWh (20.205 kWh/day) 3.440 MWh (18.625 kWh/day) -0.292 MWh (-1.580 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 204.523 kWh (29.218 kWh/day) 235.895 kWh (33.699 kWh/day) 31.372 kWh (4.482 kWh/day)
Last 30 Days (06/04/2026) 851.948 kWh (28.398 kWh/day) 825.397 kWh (27.513 kWh/day) -26.551 kWh (-0.885 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.746 MWh (21.222 kWh/day) 1.023 MWh (2.802 kWh/day)
Lifetime Since PTO 39.297 MWh (17.625 kW/day) 42.951 MWh (19.263 kW/day) 3.653 MWh (1.639 kW/day)
Lifetime Since Install 39.331 MWh 43.531 MWh 4.199 MWh
Voltage/Current 247.1 V / 13.7 A 247.1 V / 10.9 A 247.1 V / -2.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/09/2024 23:05 (13.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.493 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.250 0.948 0.244 6.977 0.000 kW
0.924 kWh
0.000 kW
5.545 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.258 0.905 0.228 6.496
03 - 202224****** IQ7+M [5] VCOP 0.000 0.255 0.942 0.243 6.768
04 - 202232****** IQ7+ [5] VCOP 0.000 0.253 0.946 0.241 6.902
05 - 202244****** IQ7+M [5] VCOP 0.000 0.244 0.887 0.222 6.032
06 - 202245****** IQ7+M [5] VCOP 0.000 0.261 0.916 0.231 6.617
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.232 0.847 0.217 6.183 0.000 kW
0.855 kWh
0.000 kW
4.275 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.237 0.856 0.218 6.246
09 - 202217****** IQ7+ [5] VCOP 0.000 0.245 0.854 0.219 6.204
10 - 202244****** IQ7+M [5] VCOP 0.000 0.257 0.856 0.218 6.228
11 - 202224****** IQ7+M [5] VCOP 0.000 0.235 0.862 0.220 6.317
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.238 0.866 0.217 6.686 0.000 kW
0.918 kWh
0.000 kW
3.673 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.253 0.911 0.231 6.927
14 - 202216****** IQ7+ [5] VCOP 0.000 0.255 0.948 0.252 7.183
15 - 202245****** IQ7+M [5] VCOP 0.000 0.259 0.948 0.248 7.170
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 26.404
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.