Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.313 kW
07/03/2025 21:41 (1863 days) Production Consumption NET Usage
Now 0.000 kW 2.313 kW 2.313 kW
Today 24.042 kWh (1.107 kW) 25.230 kWh (1.162 kW) 1.188 kWh (0.055 kW)
  - This Week 123.099 kWh (25.103 kWh/day) 154.038 kWh (31.412 kWh/day) 30.939 kWh (6.309 kWh/day)
  - This Month 65.813 kWh (22.659 kWh/day) 86.356 kWh (29.732 kWh/day) 20.543 kWh (7.073 kWh/day)
  - This Year 3.096 MWh (16.832 kWh/day) 3.214 MWh (17.474 kWh/day) 0.118 MWh (0.642 kWh/day)
Yesterday 20.789 kWh (0.866 kW) 29.763 kWh (1.240 kW) 8.974 kWh (0.374 kW)
Last 7 Days 143.248 kWh (20.464 kWh/day) 238.833 kWh (34.120 kWh/day) 95.585 kWh (13.655 kWh/day)
Last 30 Days 620.761 kWh (20.692 kWh/day) 804.732 kWh (26.825 kWh/day) 183.971 kWh (6.132 kWh/day)
Last One Year 6.324 MWh (17.327 kWh/day) 6.396 MWh (17.523 kWh/day) 0.072 MWh (0.196 kWh/day)
Lifetime Since PTO 32.546 MWh (17.461 kW/day) 35.166 MWh (18.867 kW/day) 2.619 MWh (1.405 kW/day)
Lifetime Since Install 32.580 MWh 35.746 MWh 3.165 MWh
Voltage/Current 249.4 V / 0.0 A 249.4 V / 9.3 A 249.4 V / 9.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/06/2023 23:39 (10.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.301 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.093 0.246 1.604 8.926 0.000 kW
0.238 kWh
0.000 kW
1.428 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.088 0.231 1.532 8.507
03 - 202224****** IQ7+M [0] ---- 0.000 0.092 0.244 1.584 8.808
04 - 202232****** IQ7+ [0] ---- 0.000 0.088 0.244 1.599 8.870
05 - 202244****** IQ7+M [0] ---- 0.000 0.087 0.227 1.516 8.393
06 - 202245****** IQ7+M [0] ---- 0.000 0.089 0.236 1.542 8.553
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.084 0.217 1.609 8.795 0.000 kW
0.219 kWh
0.000 kW
1.097 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.084 0.221 1.730 9.429
09 - 202217****** IQ7+ [0] ---- 0.000 0.085 0.219 1.749 9.481
10 - 202244****** IQ7+M [0] ---- 0.000 0.085 0.220 1.746 9.462
11 - 202224****** IQ7+M [0] ---- 0.000 0.086 0.220 1.775 9.633
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.081 0.225 1.014 5.882 0.000 kW
0.243 kWh
0.000 kW
0.971 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.084 0.239 1.070 6.169
14 - 202216****** IQ7+ [0] ---- 0.000 0.090 0.253 1.114 6.428
15 - 202245****** IQ7+M [0] ---- 0.000 0.088 0.254 1.112 6.416
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.231 1.806 4.679 24.829 0.000 kW
1.806 kWh
0.000 kW
1.806 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.