Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.554 kW
03/30/2026 12:53 (2133 days) Production Consumption NET Usage
Now 3.961 kW 0.407 kW -3.554 kW
Today 11.059 kWh (0.856 kW) 5.437 kWh (0.421 kW) -5.622 kWh (-0.435 kW)
  - This Week 39.188 kWh (25.488 kWh/day) 37.145 kWh (24.159 kWh/day) -2.043 kWh (-1.329 kWh/day)
  - This Month 562.320 kWh (19.038 kWh/day) 447.015 kWh (15.134 kWh/day) -115.305 kWh (-3.904 kWh/day)
  - This Year 1.196 MWh (13.511 kWh/day) 1.547 MWh (17.471 kWh/day) 0.351 MWh (3.960 kWh/day)
Yesterday 28.129 kWh (1.173 kW) 31.708 kWh (1.322 kW) 3.579 kWh (0.149 kW)
Last 7 Days 159.385 kWh (22.769 kWh/day) 90.403 kWh (12.915 kWh/day) -68.982 kWh (-9.855 kWh/day)
Last 30 Days (02/28/2026) 576.173 kWh (19.206 kWh/day) 454.819 kWh (15.161 kWh/day) -121.354 kWh (-4.045 kWh/day)
Last One Year 6.110 MWh (16.740 kWh/day) 7.838 MWh (21.473 kWh/day) 1.727 MWh (4.732 kWh/day)
Lifetime Since PTO 36.762 MWh (17.231 kW/day) 41.058 MWh (19.244 kW/day) 4.296 MWh (2.013 kW/day)
Lifetime Since Install 36.796 MWh 41.638 MWh 4.842 MWh
Voltage/Current 250.8 V / 15.8 A 250.8 V / 1.6 A 250.8 V / -14.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/18/2024 23:40 (14.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.734 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.282 1.615 1.627 12.389 0.000 kW
1.571 kWh
0.000 kW
9.427 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.280 1.544 1.553 11.659
03 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.591 1.612 12.000
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.593 1.635 12.209
05 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.520 1.527 10.933
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.564 1.577 11.921
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.283 1.535 1.522 11.449 0.000 kW
1.521 kWh
0.000 kW
7.603 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.494 1.511 11.139
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.498 1.502 11.201
10 - 202244****** IQ7+M [5] VCOP 0.000 0.278 1.529 1.512 11.409
11 - 202224****** IQ7+M [5] VCOP 0.000 0.283 1.547 1.538 11.636
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.268 1.371 1.399 11.077 0.000 kW
1.426 kWh
0.000 kW
5.704 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.290 1.409 1.452 11.200
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 1.464 1.496 11.790
15 - 202245****** IQ7+M [5] VCOP 0.000 0.263 1.461 1.499 11.794
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 10.193
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 525.0 Ah (26.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 88.5 % State Of Health 98.9 %
Run Time 14d 14h 0m to empty Report Date 2024-07-18 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.