Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.047 kW
09/22/2024 17:24 (1579 days) Production Consumption NET Usage
Now 0.332 kW 0.285 kW -0.047 kW
Today 23.379 kWh (1.342 kW) 0.714 kWh (0.041 kW) -22.665 kWh (-1.301 kW)
  - This Week 23.379 kWh (32.217 kWh/day) 0.714 kWh (0.984 kWh/day) -22.665 kWh (-31.233 kWh/day)
  - This Month 536.750 kWh (24.704 kWh/day) 280.995 kWh (12.933 kWh/day) -255.755 kWh (-11.771 kWh/day)
  - This Year 5.435 MWh (20.453 kWh/day) 4.724 MWh (17.778 kWh/day) -0.711 MWh (-2.675 kWh/day)
Yesterday 21.276 kWh (0.886 kW) 9.860 kWh (0.411 kW) -11.416 kWh (-0.476 kW)
Last 7 Days 139.259 kWh (19.894 kWh/day) 63.793 kWh (9.113 kWh/day) -75.466 kWh (-10.781 kWh/day)
Last 30 Days 703.620 kWh (23.454 kWh/day) 415.306 kWh (13.843 kWh/day) -288.314 kWh (-9.610 kWh/day)
Last One Year 6.557 MWh (17.964 kWh/day) 6.507 MWh (17.828 kWh/day) -0.050 MWh (-0.136 kWh/day)
Lifetime Since PTO 28.158 MWh (17.824 kW/day) 30.403 MWh (19.246 kW/day) 2.246 MWh (1.422 kW/day)
Lifetime Since Install 28.192 MWh 30.983 MWh 2.792 MWh
Voltage/Current 249.6 V / 1.3 A 249.5 V / 1.1 A 249.5 V / -0.2 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 02/19/2023 23:43 (10.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.053 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.225 0.781 1.609 7.169 0.000 kW
0.753 kWh
0.000 kW
4.519 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.221 0.748 1.545 6.844
03 - 202224101754 IQ7+M VCOP 0.000 0.187 0.765 1.595 7.076
04 - 202232127100 IQ7+ VCOP 0.000 0.225 0.763 1.559 6.928
05 - 202244171601 IQ7+M VCOP 0.000 0.179 0.732 1.572 6.969
06 - 202245013024 IQ7+M VCOP 0.000 0.174 0.731 1.533 6.826
front 07 - 202206091803 IQ7+ VCOP 0.000 0.239 0.776 1.666 7.218 0.000 kW
0.778 kWh
0.000 kW
3.891 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.249 0.772 1.817 7.803
09 - 202217001404 IQ7+ VCOP 0.000 0.207 0.781 1.878 8.060
10 - 202244165234 IQ7+M VCOP 0.000 0.248 0.790 1.895 8.095
11 - 202224104308 IQ7+M VCOP 0.000 0.206 0.773 1.852 7.908
back 12 - 202211186551 IQ7+ VCOP 0.000 0.140 0.659 0.876 4.308 0.000 kW
0.661 kWh
0.000 kW
2.643 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.145 0.660 0.925 4.538
14 - 202216155993 IQ7+ VCOP 0.000 0.148 0.665 0.939 4.565
15 - 202245015670 IQ7+M VCOP 0.000 0.147 0.659 0.917 4.450
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.69 V Current/Power -1.35 A (-71 W)
Remain Capacity/Energy 270.6 Ah (13.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 45.1 % State Of Health 100.0 %
Run Time 8d 8h 26m to empty Report Date 2023-02-19 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.70 V Cell (MIN/MAX) 3.286 V / 3.300 V (0.014 V)
Current/Power -0.44 A (-23 W) Runtime 8d 12h 32m to empty
Remain Capacity/Energy 90.2 Ah (4.6 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 45.1 % State Of Health 100.0 %
Temperature 19.0 °C Cycle 90
MOSFET CFET = ON, DFET = ON Reported 2023-02-19 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.286 V 3.289 V 3.288 V 3.290 V 3.290 V 3.291 V 3.292 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.295 V 3.294 V 3.298 V 3.298 V 3.300 V 3.300 V 3.300 V
pack voltage and current cell voltages
pack temperature
Voltage 52.67 V Cell (MIN/MAX) 3.291 V / 3.293 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 19.2 °C Cycle 35
MOSFET CFET = ON, DFET = ON Reported 2023-02-19 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.292 V 3.292 V 3.292 V 3.293 V 3.292 V 3.292 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.291 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V
pack voltage and current cell voltages
pack temperature
Voltage 52.70 V Cell (MIN/MAX) 3.293 V / 3.295 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 20.4 °C Cycle 37
MOSFET CFET = ON, DFET = ON Reported 2023-02-19 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.293 V 3.294 V 3.295 V 3.293 V 3.294 V 3.293 V 3.293 V 3.294 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.293 V 3.293 V 3.294 V 3.293 V 3.293 V 3.293 V 3.293 V
pack voltage and current cell voltages
pack temperature
Voltage 52.69 V Cell (MIN/MAX) 3.292 V / 3.293 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 21.7 °C Cycle 37
MOSFET CFET = ON, DFET = ON Reported 2023-02-19 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V 3.293 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.293 V 3.293 V 3.292 V 3.293 V 3.293 V 3.293 V 3.293 V
pack voltage and current cell voltages
pack temperature
Voltage 52.67 V Cell (MIN/MAX) 3.291 V / 3.292 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.2 Ah (5.1 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.7 %
Temperature 19.9 °C Cycle 37
MOSFET CFET = ON, DFET = ON Reported 2023-02-19 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.291 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.291 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V 3.292 V
pack voltage and current cell voltages
pack temperature