Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.200 kW
09/13/2025 08:06 (1935 days) Production Consumption NET Usage
Now 0.501 kW 0.301 kW -0.200 kW
Today 0.336 kWh (0.041 kW) 2.984 kWh (0.368 kW) 2.648 kWh (0.326 kW)
  - This Week 126.730 kWh (19.995 kWh/day) 87.648 kWh (13.829 kWh/day) -39.082 kWh (-6.166 kWh/day)
  - This Month 263.658 kWh (21.370 kWh/day) 283.373 kWh (22.968 kWh/day) 19.715 kWh (1.598 kWh/day)
  - This Year 4.771 MWh (18.685 kWh/day) 5.454 MWh (21.360 kWh/day) 0.683 MWh (2.675 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.222 MWh (17.683 kW/day) 37.406 MWh (19.328 kW/day) 3.184 MWh (1.645 kW/day)
Lifetime Since Install 34.256 MWh 37.986 MWh 3.730 MWh
Voltage/Current 252.7 V / 2.0 A 252.7 V / 1.2 A 252.7 V / -0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/22/2024 23:35 (16.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.998 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.238 1.019 0.778 5.202 0.000 kW
0.987 kWh
0.000 kW
5.920 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.231 0.964 0.732 4.886
03 - 202224****** IQ7+M [5] VCOP 0.000 0.240 1.004 0.771 5.047
04 - 202232****** IQ7+ [5] VCOP 0.000 0.240 1.008 0.768 5.037
05 - 202244****** IQ7+M [5] VCOP 0.000 0.233 0.950 0.720 5.835
06 - 202245****** IQ7+M [5] VCOP 0.000 0.235 0.975 0.747 6.071
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.264 0.993 0.822 7.039 0.000 kW
1.055 kWh
0.000 kW
5.273 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.270 1.063 0.833 7.549
09 - 202217****** IQ7+ [5] VCOP 0.000 0.265 1.081 0.829 10.216
10 - 202244****** IQ7+M [5] VCOP 0.000 0.262 1.070 0.829 10.359
11 - 202224****** IQ7+M [5] VCOP 0.000 0.266 1.066 0.836 10.004
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.152 0.724 0.549 2.690 0.000 kW
0.770 kWh
0.000 kW
3.078 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.159 0.764 0.592 2.877
14 - 202216****** IQ7+ [5] VCOP 0.000 0.165 0.800 0.629 2.962
15 - 202245****** IQ7+M [5] VCOP 0.000 0.162 0.790 0.622 2.965
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.727 0.000 13.561 0.000 kW
1.727 kWh
0.000 kW
1.727 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -0.72 A (-38 W)
Remain Capacity/Energy 530.1 Ah (27.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 89.4 % State Of Health 98.9 %
Run Time 30d 16h 15m to empty Report Date 2024-02-22 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.