Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 4.672 kW
09/22/2024 13:27 (1579 days) Production Consumption NET Usage
Now 3.497 kW -1.175 kW -4.672 kW
Today 12.943 kWh (0.962 kW) 1.663 kWh (0.124 kW) -11.280 kWh (-0.839 kW)
  - This Week 12.943 kWh (23.092 kWh/day) 1.663 kWh (2.967 kWh/day) -11.280 kWh (-20.125 kWh/day)
  - This Month 526.314 kWh (24.409 kWh/day) 281.944 kWh (13.076 kWh/day) -244.370 kWh (-11.333 kWh/day)
  - This Year 5.425 MWh (20.427 kWh/day) 4.725 MWh (17.793 kWh/day) -0.699 MWh (-2.634 kWh/day)
Yesterday 21.276 kWh (0.886 kW) 9.860 kWh (0.411 kW) -11.416 kWh (-0.476 kW)
Last 7 Days 139.259 kWh (19.894 kWh/day) 63.793 kWh (9.113 kWh/day) -75.466 kWh (-10.781 kWh/day)
Last 30 Days 703.620 kWh (23.454 kWh/day) 415.306 kWh (13.843 kWh/day) -288.314 kWh (-9.610 kWh/day)
Last One Year 6.557 MWh (17.964 kWh/day) 6.507 MWh (17.828 kWh/day) -0.050 MWh (-0.136 kWh/day)
Lifetime Since PTO 28.147 MWh (17.820 kW/day) 30.404 MWh (19.249 kW/day) 2.257 MWh (1.429 kW/day)
Lifetime Since Install 28.181 MWh 30.984 MWh 2.803 MWh
Voltage/Current 250.7 V / 14.0 A 250.8 V / -4.7 A 250.7 V / -18.6 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 03/25/2023 22:34 (15.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.234 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.044 0.131 1.146 10.440 0.000 kW
0.121 kWh
0.000 kW
0.729 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.041 0.116 1.087 10.006
03 - 202224101754 IQ7+M VCOP 0.000 0.044 0.130 1.131 10.378
04 - 202232127100 IQ7+ VCOP 0.000 0.044 0.126 1.130 10.399
05 - 202244171601 IQ7+M VCOP 0.000 0.040 0.113 1.078 9.775
06 - 202245013024 IQ7+M VCOP 0.000 0.041 0.113 1.098 9.895
front 07 - 202206091803 IQ7+ VCOP 0.000 0.038 0.117 1.198 10.043 0.000 kW
0.120 kWh
0.000 kW
0.598 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.039 0.120 1.204 10.684
09 - 202217001404 IQ7+ VCOP 0.000 0.039 0.121 1.203 10.694
10 - 202244165234 IQ7+M VCOP 0.000 0.040 0.120 1.204 10.804
11 - 202224104308 IQ7+M VCOP 0.000 0.040 0.120 1.213 10.868
back 12 - 202211186551 IQ7+ VCOP 0.000 0.039 0.108 0.805 7.604 0.000 kW
0.128 kWh
0.000 kW
0.512 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.043 0.124 0.843 7.915
14 - 202216155993 IQ7+ VCOP 0.000 0.046 0.140 0.893 8.303
15 - 202245015670 IQ7+M VCOP 0.000 0.046 0.139 0.890 8.275
wind 16 - 122214035120 IQ7PD ---- 0.000 0.234 3.396 3.657 26.249 0.000 kW
3.396 kWh
0.000 kW
3.396 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.01 V Current/Power -2.10 A (-0.109 kW)
Remain Capacity/Energy 122.1 Ah (6.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 20.4 % State Of Health 100.0 %
Run Time 2d 10h 9m to empty Report Date 2023-03-25 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.01 V Cell (MIN/MAX) 3.238 V / 3.260 V (0.022 V)
Current/Power -0.59 A (-30 W) Runtime 2d 20h 52m to empty
Remain Capacity/Energy 40.7 Ah (2.1 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 20.4 % State Of Health 100.0 %
Temperature 19.0 °C Cycle 92
MOSFET CFET = ON, DFET = ON Reported 2023-03-25 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.238 V 3.244 V 3.246 V 3.244 V 3.250 V 3.246 V 3.251 V 3.250 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.252 V 3.250 V 3.254 V 3.252 V 3.253 V 3.257 V 3.260 V 3.257 V
pack voltage and current cell voltages
pack temperature
Voltage 52.02 V Cell (MIN/MAX) 3.246 V / 3.255 V (0.009 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 38.8 Ah (2.0 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 39.0 % State Of Health 99.5 %
Temperature 18.8 °C Cycle 37
MOSFET CFET = ON, DFET = ON Reported 2023-03-25 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.252 V 3.248 V 3.253 V 3.246 V 3.253 V 3.254 V 3.248 V 3.255 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.248 V 3.253 V 3.253 V 3.252 V 3.251 V 3.253 V 3.249 V
pack voltage and current cell voltages
pack temperature
Voltage 52.03 V Cell (MIN/MAX) 3.247 V / 3.255 V (0.008 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 38.0 Ah (1.9 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 38.2 % State Of Health 99.5 %
Temperature 20.1 °C Cycle 39
MOSFET CFET = ON, DFET = ON Reported 2023-03-25 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.253 V 3.253 V 3.253 V 3.248 V 3.252 V 3.248 V 3.253 V 3.255 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.253 V 3.255 V 3.253 V 3.253 V 3.250 V 3.247 V 3.251 V 3.251 V
pack voltage and current cell voltages
pack temperature
Voltage 52.02 V Cell (MIN/MAX) 3.247 V / 3.255 V (0.008 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 39.8 Ah (2.0 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 40.0 % State Of Health 99.5 %
Temperature 21.2 °C Cycle 40
MOSFET CFET = ON, DFET = ON Reported 2023-03-25 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.247 V 3.253 V 3.250 V 3.255 V 3.250 V 3.253 V 3.251 V 3.251 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.250 V 3.250 V 3.250 V 3.254 V 3.251 V 3.252 V 3.252 V
pack voltage and current cell voltages
pack temperature
Voltage 51.99 V Cell (MIN/MAX) 3.245 V / 3.251 V (0.006 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 37.0 Ah (1.9 kWh) Full Capacity/Energy 99.2 Ah (5.1 kWh)
State Of Charge 37.3 % State Of Health 99.2 %
Temperature 19.5 °C Cycle 39
MOSFET CFET = ON, DFET = ON Reported 2023-03-25 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.245 V 3.251 V 3.248 V 3.250 V 3.250 V 3.250 V 3.248 V 3.251 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.250 V 3.250 V 3.248 V 3.248 V 3.250 V 3.250 V 3.250 V 3.250 V
pack voltage and current cell voltages
pack temperature