Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.683 kW
12/21/2025 20:57 (2034 days) Production Consumption NET Usage
Now 0.000 kW 0.683 kW 0.683 kW
Today 9.597 kWh (0.458 kW) 14.830 kWh (0.707 kW) 5.233 kWh (0.250 kW)
  - This Week 9.597 kWh (10.986 kWh/day) 14.830 kWh (16.977 kWh/day) 5.233 kWh (5.991 kWh/day)
  - This Month 184.503 kWh (8.839 kWh/day) 438.111 kWh (20.989 kWh/day) 253.608 kWh (12.150 kWh/day)
  - This Year 6.053 MWh (17.058 kWh/day) 7.354 MWh (20.724 kWh/day) 1.301 MWh (3.666 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.504 MWh (17.448 kW/day) 39.307 MWh (19.316 kW/day) 3.803 MWh (1.869 kW/day)
Lifetime Since Install 35.538 MWh 39.887 MWh 4.349 MWh
Voltage/Current 248.9 V / 0.0 A 248.9 V / 2.7 A 248.9 V / 2.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/29/2025 23:43 (10.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.391 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.215 0.802 0.671 6.935 0.000 kW
0.772 kWh
0.000 kW
4.634 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.221 0.752 0.636 6.600
03 - 202224****** IQ7+M [0] ---- 0.000 0.223 0.768 0.654 6.782
04 - 202232****** IQ7+ [0] ---- 0.000 0.215 0.759 0.647 6.790
05 - 202244****** IQ7+M [0] ---- 0.000 0.217 0.754 0.634 6.614
06 - 202245****** IQ7+M [0] ---- 0.000 0.220 0.799 0.662 6.795
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.263 0.833 0.564 6.215 0.000 kW
0.890 kWh
0.000 kW
4.450 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.262 0.898 0.665 7.151
09 - 202217****** IQ7+ [0] ---- 0.000 0.265 0.906 0.723 7.557
10 - 202244****** IQ7+M [0] ---- 0.000 0.264 0.905 0.720 7.510
11 - 202224****** IQ7+M [0] ---- 0.000 0.264 0.909 0.684 7.375
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.138 0.538 0.508 4.605 0.000 kW
0.577 kWh
0.000 kW
2.307 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.145 0.574 0.532 4.874
14 - 202216****** IQ7+ [0] ---- 0.000 0.148 0.597 0.552 5.025
15 - 202245****** IQ7+M [0] ---- 0.000 0.147 0.598 0.549 4.995
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 1.46 V Voltage Charge 52.29 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.8 °C / 26.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-29 23:59
voltage in/out power and energy

Battery History
Voltage 52.51 V Current/Power -6.45 A (-0.339 kW)
Remain Capacity/Energy 320.4 Ah (16.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 54.0 % State Of Health 98.9 %
Run Time 2d 1h 40m to empty Report Date 2025-10-29 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.