Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.004 kW
03/21/2026 10:05 (2124 days) Production Consumption NET Usage
Now 1.137 kW 0.133 kW -1.004 kW
Today 2.260 kWh (0.224 kW) 5.368 kWh (0.532 kW) 3.108 kWh (0.308 kW)
  - This Week 115.997 kWh (18.067 kWh/day) 123.684 kWh (19.264 kWh/day) 7.687 kWh (1.197 kWh/day)
  - This Month 350.718 kWh (17.175 kWh/day) 327.711 kWh (16.048 kWh/day) -23.007 kWh (-1.127 kWh/day)
  - This Year 0.985 MWh (12.398 kWh/day) 1.428 MWh (17.974 kWh/day) 0.443 MWh (5.577 kWh/day)
Yesterday 19.934 kWh (0.831 kW) 13.045 kWh (0.544 kW) -6.889 kWh (-0.287 kW)
Last 7 Days 144.915 kWh (20.702 kWh/day) 132.971 kWh (18.996 kWh/day) -11.944 kWh (-1.706 kWh/day)
Last 30 Days (02/19/2026) 453.079 kWh (15.103 kWh/day) 501.140 kWh (16.705 kWh/day) 48.061 kWh (1.602 kWh/day)
Last One Year 6.082 MWh (16.664 kWh/day) 7.891 MWh (21.618 kWh/day) 1.808 MWh (4.954 kWh/day)
Lifetime Since PTO 36.550 MWh (17.205 kW/day) 40.938 MWh (19.270 kW/day) 4.388 MWh (2.065 kW/day)
Lifetime Since Install 36.584 MWh 41.518 MWh 4.934 MWh
Voltage/Current 250.0 V / 4.5 A 250.1 V / 0.5 A 250.1 V / -4.0 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 01/31/2026 23:57 (23.9 hours) Number of Devices 17 set
Current Power 0.320 kW (0.019 kW/panel) Today Energy 18.756 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.193 0.649 0.402 1.626 0.000 kW
0.789 kWh
0.000 kW
4.733 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.156 0.297 0.055 1.104
03 - 202224****** IQ7+M [5] VCOP 0.000 0.232 0.932 0.439 1.661
04 - 202232****** IQ7+ [5] VCOP 0.000 0.244 1.176 1.337 3.470
05 - 202244****** IQ7+M [5] VCOP 0.000 0.223 0.821 0.569 1.789
06 - 202245****** IQ7+M [5] VCOP 0.000 0.217 0.858 0.515 1.909
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.114 0.536 0.441 1.831 0.000 kW
1.120 kWh
0.000 kW
5.600 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.269 1.164 0.775 2.264
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.333 0.467 1.869
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.513 1.449 3.151
11 - 202224****** IQ7+M [5] VCOP 0.000 0.237 1.053 0.993 2.424
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.001 0.004 0.002 0.438 0.000 kW
0.003 kWh
0.000 kW
0.014 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.001 0.002 0.000 0.515
14 - 202216****** IQ7+ [5] VCOP 0.000 0.001 0.003 0.000 0.532
15 - 202245****** IQ7+M [5] VCOP 0.000 0.002 0.005 0.005 0.541
wind 16 - 202320****** IQ7XS [0] ---- 0.320 0.322 7.689 7.650 10.436 0.160 kW
4.205 kWh
0.320 kW
8.410 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.189 0.721 0.905 3.557
Panel Layout Each Group Production

Charger History
Voltage PV 2.53 V Voltage Charge 52.17 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.0 °C / 22.1 °C Flags 00/00/00 Energy Today 6.733 kWh @ 2026-01-31 23:55
voltage in/out power and energy

Battery History
Voltage 52.43 V Current/Power -8.13 A (-0.426 kW)
Remain Capacity/Energy 359.2 Ah (18.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 60.6 % State Of Health 98.9 %
Run Time 1d 20h 10m to empty Report Date 2026-01-31 23:54
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.40 V Cell (MIN/MAX) 3.267 V / 3.283 V (0.016 V)
Current/Power -2.29 A (-119 W) Runtime 2d 4h 22m to empty
Remain Capacity/Energy 119.7 Ah (6.1 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 60.6 % State Of Health 98.8 %
Temperature 13.5 °C Cycle 232
MOSFET CFET = ON, DFET = ON Reported 2026-01-31 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.268 V 3.267 V 3.269 V 3.269 V 3.274 V 3.271 V 3.272 V 3.274 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.276 V 3.274 V 3.278 V 3.277 V 3.280 V 3.279 V 3.283 V 3.282 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.