Importing from grid by 0.166 kW
03/18/2026 18:46 (2121 days) Production Consumption NET Usage
Now 0.388 kW 0.554 kW 0.166 kW
Today 29.220 kWh (1.556 kW) 13.741 kWh (0.732 kW) -15.479 kWh (-0.824 kW)
  - This Week 78.737 kWh (20.816 kWh/day) 87.479 kWh (23.127 kWh/day) 8.742 kWh (2.311 kWh/day)
  - This Month 313.458 kWh (17.627 kWh/day) 291.506 kWh (16.393 kWh/day) -21.952 kWh (-1.234 kWh/day)
  - This Year 0.947 MWh (12.338 kWh/day) 1.391 MWh (18.120 kWh/day) 0.444 MWh (5.782 kWh/day)
Yesterday 32.413 kWh (1.350 kW) 46.628 kWh (1.943 kW) 14.215 kWh (0.592 kW)
Last 7 Days 145.429 kWh (20.776 kWh/day) 131.114 kWh (18.731 kWh/day) -14.315 kWh (-2.045 kWh/day)
Last 30 Days (02/16/2026) 438.174 kWh (14.606 kWh/day) 499.040 kWh (16.635 kWh/day) 60.866 kWh (2.029 kWh/day)
Last One Year 6.084 MWh (16.668 kWh/day) 7.887 MWh (21.607 kWh/day) 1.803 MWh (4.939 kWh/day)
Lifetime Since PTO 36.513 MWh (17.209 kW/day) 40.902 MWh (19.277 kW/day) 4.389 MWh (2.069 kW/day)
Lifetime Since Install 36.547 MWh 41.482 MWh 4.935 MWh
Voltage/Current 250.4 V / 1.5 A 250.3 V / 2.2 A 250.4 V / 0.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/02/2026 23:32 (18.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.590 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.247 1.350 1.270 2.507 0.000 kW
1.318 kWh
0.000 kW
7.906 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.239 1.292 1.213 1.627
03 - 202224****** IQ7+M [5] VCOP 0.000 0.245 1.326 1.284 2.844
04 - 202232****** IQ7+ [5] VCOP 0.000 0.244 1.321 1.281 4.900
05 - 202244****** IQ7+M [5] VCOP 0.000 0.238 1.297 1.243 2.853
06 - 202245****** IQ7+M [5] VCOP 0.000 0.243 1.320 1.252 3.503
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.246 0.953 0.660 1.816 0.000 kW
1.512 kWh
0.000 kW
7.558 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.585 1.536 3.702
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.750 1.655 3.546
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.701 1.631 4.988
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.569 1.494 3.664
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.002 0.008 0.005 0.016 0.000 kW
0.007 kWh
0.000 kW
0.026 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.001 0.004 0.002 0.004
14 - 202216****** IQ7+ [5] VCOP 0.000 0.002 0.007 0.004 0.007
15 - 202245****** IQ7+M [5] VCOP 0.000 0.002 0.009 0.006 0.027
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.322 5.216 7.659 25.783 0.000 kW
3.049 kWh
0.000 kW
6.099 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.204 0.883 0.854 4.210
Panel Layout Each Group Production

Charger History
Voltage PV 1.55 V Voltage Charge 52.34 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 24.5 °C / 20.7 °C Flags 00/00/00 Energy Today 4.559 kWh @ 2026-02-02 23:56
voltage in/out power and energy

Battery History
Voltage 52.50 V Current/Power -1.68 A (-88 W)
Remain Capacity/Energy 268.5 Ah (13.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 45.3 % State Of Health 98.9 %
Run Time 6d 15h 49m to empty Report Date 2026-02-02 23:54