Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.229 kW
09/13/2025 08:08 (1935 days) Production Consumption NET Usage
Now 0.534 kW 0.305 kW -0.229 kW
Today 0.354 kWh (0.043 kW) 2.995 kWh (0.368 kW) 2.641 kWh (0.324 kW)
  - This Week 126.748 kWh (19.993 kWh/day) 87.659 kWh (13.827 kWh/day) -39.089 kWh (-6.166 kWh/day)
  - This Month 263.676 kWh (21.369 kWh/day) 283.384 kWh (22.966 kWh/day) 19.708 kWh (1.597 kWh/day)
  - This Year 4.771 MWh (18.685 kWh/day) 5.454 MWh (21.360 kWh/day) 0.683 MWh (2.675 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.222 MWh (17.683 kW/day) 37.406 MWh (19.328 kW/day) 3.184 MWh (1.645 kW/day)
Lifetime Since Install 34.256 MWh 37.986 MWh 3.730 MWh
Voltage/Current 252.8 V / 2.1 A 252.8 V / 1.2 A 252.8 V / -0.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/01/2024 23:57 (23.9 hours) Number of Devices 16 set
Current Power 0.229 kW (0.014 kW/panel) Today Energy 37.894 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.311 1.164 12.589 0.000 kW
2.176 kWh
0.000 kW
13.054 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 2.157 1.103 11.804
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.179 1.130 11.969
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.228 1.141 12.164
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.949 0.974 10.629
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 2.229 1.121 12.113
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 2.086 1.000 11.247 0.000 kW
2.059 kWh
0.000 kW
10.293 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.979 1.005 10.993
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 2.015 1.003 11.094
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 2.080 1.004 11.207
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.133 1.015 11.394
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.285 2.224 1.165 12.021 0.000 kW
2.275 kWh
0.000 kW
9.100 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.288 2.204 1.215 12.200
14 - 202216****** IQ7+ [5] VCOP 0.000 0.287 2.340 1.258 12.761
15 - 202245****** IQ7+M [5] VCOP 0.000 0.294 2.331 1.261 12.738
wind 16 - 122214****** IQ7PD [5] VCOP 0.229 0.230 5.446 0.000 0.000 0.229 kW
5.446 kWh
0.229 kW
5.446 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.56 V Current/Power -6.28 A (-0.330 kW)
Remain Capacity/Energy 279.6 Ah (14.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 47.1 % State Of Health 98.9 %
Run Time 1d 20h 31m to empty Report Date 2024-07-01 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.