Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.161 kW
02/14/2026 14:56 (2089 days) Production Consumption NET Usage
Now 2.541 kW 0.380 kW -2.161 kW
Today 14.985 kWh (1.002 kW) 7.763 kWh (0.519 kW) -7.222 kWh (-0.483 kW)
  - This Week 128.227 kWh (19.361 kWh/day) 140.095 kWh (21.153 kWh/day) 11.868 kWh (1.792 kWh/day)
  - This Month 240.059 kWh (17.621 kWh/day) 281.354 kWh (20.652 kWh/day) 41.295 kWh (3.031 kWh/day)
  - This Year 0.485 MWh (10.880 kWh/day) 0.865 MWh (19.374 kWh/day) 0.379 MWh (8.495 kWh/day)
Yesterday 19.344 kWh (0.806 kW) 37.272 kWh (1.552 kW) 17.928 kWh (0.747 kW)
Last 7 Days 132.470 kWh (20.773 kWh/day) 145.988 kWh (22.893 kWh/day) 13.518 kWh (2.120 kWh/day)
Last 30 Days 341.516 kWh (11.625 kWh/day) 596.656 kWh (20.310 kWh/day) 255.140 kWh (8.685 kWh/day)
Last One Year 6.189 MWh (16.986 kWh/day) 7.634 MWh (20.951 kWh/day) 1.445 MWh (3.965 kWh/day)
Lifetime Since PTO 36.051 MWh (17.252 kW/day) 40.376 MWh (19.322 kW/day) 4.325 MWh (2.070 kW/day)
Lifetime Since Install 36.085 MWh 40.956 MWh 4.871 MWh
Voltage/Current 252.0 V / 10.1 A 252.1 V / 1.5 A 252.1 V / -8.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/03/2024 23:07 (19.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.203 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.220 0.706 1.009 4.716 0.000 kW
0.683 kWh
0.000 kW
4.101 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.210 0.664 0.962 4.504
03 - 202224****** IQ7+M [5] VCOP 0.000 0.219 0.691 1.006 4.682
04 - 202232****** IQ7+ [5] VCOP 0.000 0.218 0.695 1.017 4.716
05 - 202244****** IQ7+M [5] VCOP 0.000 0.221 0.664 0.967 4.531
06 - 202245****** IQ7+M [5] VCOP 0.000 0.223 0.681 0.978 4.611
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 0.703 1.014 5.071 0.000 kW
0.791 kWh
0.000 kW
3.955 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 0.816 1.171 5.618
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 0.813 1.261 5.906
10 - 202244****** IQ7+M [5] VCOP 0.000 0.288 0.812 1.238 5.868
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 0.811 1.160 5.620
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.107 0.381 0.368 1.902 0.000 kW
0.417 kWh
0.000 kW
1.668 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.112 0.419 0.444 2.241
14 - 202216****** IQ7+ [5] VCOP 0.000 0.113 0.436 0.470 2.503
15 - 202245****** IQ7+M [5] VCOP 0.000 0.122 0.432 0.460 2.484
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
2.240 kWh
0.000 kW
4.480 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.230 4.480 5.490 11.237
Panel Layout Each Group Production

Charger History
Voltage PV 0.46 V Voltage Charge 52.19 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.8 °C / 24.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-12-03 23:56
voltage in/out power and energy

Battery History
Voltage 52.44 V Current/Power -6.22 A (-0.326 kW)
Remain Capacity/Energy 338.4 Ah (17.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.1 % State Of Health 98.9 %
Run Time 2d 6h 24m to empty Report Date 2024-12-03 23:56
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.