Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.263 kW
09/22/2024 04:38 (1579 days) Production Consumption NET Usage
Now 0.000 kW 0.263 kW 0.263 kW
Today 0.000 kWh (0.000 kW) 1.727 kWh (0.372 kW) 1.727 kWh (0.372 kW)
  - This Week 0.000 kWh (0.000 kWh/day) 1.727 kWh (8.938 kWh/day) 1.727 kWh (8.938 kWh/day)
  - This Month 513.371 kWh (24.222 kWh/day) 282.008 kWh (13.306 kWh/day) -231.363 kWh (-10.916 kWh/day)
  - This Year 5.412 MWh (20.406 kWh/day) 4.725 MWh (17.818 kWh/day) -0.686 MWh (-2.588 kWh/day)
Yesterday 21.276 kWh (0.886 kW) 9.860 kWh (0.411 kW) -11.416 kWh (-0.476 kW)
Last 7 Days 139.259 kWh (19.894 kWh/day) 63.793 kWh (9.113 kWh/day) -75.466 kWh (-10.781 kWh/day)
Last 30 Days 703.620 kWh (23.454 kWh/day) 415.306 kWh (13.843 kWh/day) -288.314 kWh (-9.610 kWh/day)
Last One Year 6.557 MWh (17.964 kWh/day) 6.507 MWh (17.828 kWh/day) -0.050 MWh (-0.136 kWh/day)
Lifetime Since PTO 28.134 MWh (17.816 kW/day) 30.404 MWh (19.253 kW/day) 2.270 MWh (1.437 kW/day)
Lifetime Since Install 28.168 MWh 30.984 MWh 2.816 MWh
Voltage/Current 251.6 V / 0.0 A 251.5 V / 1.0 A 251.6 V / 1.0 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 07/19/2023 23:37 (14.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.512 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.265 1.088 1.425 10.413 0.000 kW
1.061 kWh
0.000 kW
6.366 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.253 1.035 1.356 9.830
03 - 202224101754 IQ7+M ---- 0.000 0.261 1.077 1.400 10.091
04 - 202232127100 IQ7+ ---- 0.000 0.266 1.085 1.413 10.253
05 - 202244171601 IQ7+M ---- 0.000 0.252 1.025 1.260 9.290
06 - 202245013024 IQ7+M ---- 0.000 0.259 1.055 1.376 10.084
front 07 - 202206091803 IQ7+ ---- 0.000 0.274 1.034 1.307 9.476 0.000 kW
1.038 kWh
0.000 kW
5.188 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.275 1.025 1.277 9.474
09 - 202217001404 IQ7+ ---- 0.000 0.273 1.035 1.288 9.493
10 - 202244165234 IQ7+M ---- 0.000 0.267 1.042 1.320 9.510
11 - 202224104308 IQ7+M ---- 0.000 0.274 1.051 1.329 9.634
back 12 - 202211186551 IQ7+ ---- 0.000 0.213 0.910 1.267 9.632 0.000 kW
0.956 kWh
0.000 kW
3.825 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.220 0.940 1.308 9.844
14 - 202216155993 IQ7+ ---- 0.000 0.223 0.987 1.366 10.184
15 - 202245015670 IQ7+M ---- 0.000 0.227 0.988 1.375 10.230
wind 16 - 122214035120 IQ7PD ---- 0.000 0.230 1.133 1.137 8.017 0.000 kW
1.133 kWh
0.000 kW
1.133 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.