Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.464 kW
06/18/2026 16:13 (2213 days) Production Consumption NET Usage
Now 3.819 kW 2.355 kW -1.464 kW
Today 15.303 kWh (0.943 kW) 6.408 kWh (0.395 kW) -8.895 kWh (-0.548 kW)
  - This Week 134.073 kWh (28.671 kWh/day) 59.778 kWh (12.783 kWh/day) -74.295 kWh (-15.888 kWh/day)
  - This Month 592.425 kWh (33.513 kWh/day) 442.659 kWh (25.041 kWh/day) -149.766 kWh (-8.472 kWh/day)
  - This Year 3.327 MWh (19.723 kWh/day) 3.013 MWh (17.860 kWh/day) -0.314 MWh (-1.863 kWh/day)
Yesterday 26.257 kWh (1.094 kW) 15.040 kWh (0.627 kW) -11.217 kWh (-0.467 kW)
Last 7 Days 195.769 kWh (27.967 kWh/day) 175.573 kWh (25.082 kWh/day) -20.196 kWh (-2.885 kWh/day)
Last 30 Days (05/19/2026) 884.665 kWh (29.489 kWh/day) 685.302 kWh (22.843 kWh/day) -199.363 kWh (-6.645 kWh/day)
Last One Year 6.697 MWh (18.348 kWh/day) 7.872 MWh (21.567 kWh/day) 1.175 MWh (3.219 kWh/day)
Lifetime Since PTO 38.893 MWh (17.569 kW/day) 42.523 MWh (19.209 kW/day) 3.631 MWh (1.640 kW/day)
Lifetime Since Install 38.926 MWh 43.103 MWh 4.177 MWh
Voltage/Current 249.0 V / 15.3 A 248.9 V / 9.5 A 248.9 V / -5.9 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 08/25/2025 23:59 (24.0 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 33.093 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.969 1.313 10.403 0.000 kW
1.907 kWh
0.000 kW
11.441 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.875 1.252 9.899
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.931 1.308 10.323
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.953 1.347 10.547
05 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.818 1.183 9.536
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.895 1.245 9.973
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.922 1.205 9.963 0.000 kW
1.939 kWh
0.000 kW
9.696 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.924 1.255 10.033
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.914 1.256 9.979
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.949 1.260 10.187
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.988 1.269 10.403
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.581 1.264 8.882 0.000 kW
1.610 kWh
0.000 kW
6.441 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.265 1.590 1.293 8.960
14 - 202216****** IQ7+ [5] VCOP 0.000 0.256 1.636 1.333 9.315
15 - 202245****** IQ7+M [5] VCOP 0.000 0.263 1.634 1.342 9.341
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.757 kWh
0.230 kW
5.515 kWh
17 - 122214****** IQ7PD [4] VCOP 0.230 0.231 5.515 5.486 38.418
Panel Layout Each Group Production

Charger History
Voltage PV 0.37 V Voltage Charge 52.85 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.8 °C / 29.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-25 23:58
voltage in/out power and energy

Battery History
Voltage 53.13 V Current/Power -6.31 A (-0.335 kW)
Remain Capacity/Energy 501.2 Ah (25.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 84.5 % State Of Health 98.9 %
Run Time 3d 7h 25m to empty Report Date 2025-08-25 23:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.13 V Cell (MIN/MAX) 3.315 V / 3.325 V (0.010 V)
Current/Power -1.93 A (-102 W) Runtime 3d 14h 36m to empty
Remain Capacity/Energy 167.1 Ah (8.6 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 84.5 % State Of Health 98.8 %
Temperature 26.0 °C Cycle 214
MOSFET CFET = ON, DFET = ON Reported 2025-08-25 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.316 V 3.315 V 3.316 V 3.317 V 3.319 V 3.317 V 3.318 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.321 V 3.321 V 3.322 V 3.322 V 3.324 V 3.322 V 3.325 V 3.324 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt1_1.png". Check that the process running PHP has enough permission.