Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.855 kW
09/18/2025 10:08 (1940 days) Production Consumption NET Usage
Now 2.159 kW 0.304 kW -1.855 kW
Today 2.844 kWh (0.281 kW) 4.602 kWh (0.454 kW) 1.758 kWh (0.173 kW)
  - This Week 74.133 kWh (16.760 kWh/day) 103.295 kWh (23.353 kWh/day) 29.162 kWh (6.593 kWh/day)
  - This Month 359.902 kWh (20.658 kWh/day) 407.852 kWh (23.410 kWh/day) 47.950 kWh (2.752 kWh/day)
  - This Year 4.867 MWh (18.690 kWh/day) 5.579 MWh (21.421 kWh/day) 0.711 MWh (2.732 kWh/day)
Yesterday 10.403 kWh (0.433 kW) 11.414 kWh (0.476 kW) 1.011 kWh (0.042 kW)
Last 7 Days 141.039 kWh (20.148 kWh/day) 153.970 kWh (21.996 kWh/day) 12.931 kWh (1.847 kWh/day)
Last 30 Days 663.517 kWh (22.117 kWh/day) 687.473 kWh (22.916 kWh/day) 23.956 kWh (0.799 kWh/day)
Last One Year 6.255 MWh (17.136 kWh/day) 7.166 MWh (19.634 kWh/day) 0.912 MWh (2.498 kWh/day)
Lifetime Since PTO 34.318 MWh (17.686 kW/day) 37.531 MWh (19.341 kW/day) 3.212 MWh (1.656 kW/day)
Lifetime Since Install 34.352 MWh 38.111 MWh 3.759 MWh
Voltage/Current 252.2 V / 8.6 A 252.0 V / 1.2 A 252.1 V / -7.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/06/2025 23:49 (8.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.244 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.048 0.156 0.631 4.812 0.000 kW
0.161 kWh
0.000 kW
0.964 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.047 0.156 0.606 4.563
03 - 202224****** IQ7+M [5] VCOP 0.000 0.048 0.159 0.648 4.783
04 - 202232****** IQ7+ [5] VCOP 0.000 0.044 0.146 0.651 4.798
05 - 202244****** IQ7+M [5] VCOP 0.000 0.054 0.168 0.612 4.552
06 - 202245****** IQ7+M [5] VCOP 0.000 0.058 0.180 0.607 4.626
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.047 0.151 0.795 4.956 0.000 kW
0.167 kWh
0.000 kW
0.835 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.052 0.168 0.805 5.445
09 - 202217****** IQ7+ [5] VCOP 0.000 0.058 0.175 0.829 5.693
10 - 202244****** IQ7+M [5] VCOP 0.000 0.054 0.176 0.830 5.629
11 - 202224****** IQ7+M [5] VCOP 0.000 0.051 0.164 0.834 5.384
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.024 0.105 0.263 2.275 0.000 kW
0.111 kWh
0.000 kW
0.445 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.026 0.111 0.298 2.568
14 - 202216****** IQ7+ [5] VCOP 0.000 0.027 0.115 0.311 2.672
15 - 202245****** IQ7+M [5] VCOP 0.000 0.027 0.113 0.310 2.635
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.21 V Voltage Charge 51.41 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.2 °C / 22.8 °C Flags 00/00/00 Energy Today 0.732 kWh @ 2025-01-06 23:57
voltage in/out power and energy

Battery History
Voltage 51.59 V Current/Power -1.20 A (-61 W)
Remain Capacity/Energy 87.6 Ah (4.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 14.8 % State Of Health 98.9 %
Run Time 3d 0h 59m to empty Report Date 2025-01-06 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.