Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.392 kW
06/30/2026 02:40 (2225 days) Production Consumption NET Usage
Now 0.000 kW 0.392 kW 0.392 kW
Today 0.000 kWh (0.000 kW) 1.752 kWh (0.656 kW) 1.752 kWh (0.656 kW)
  - This Week 54.728 kWh (25.919 kWh/day) 54.563 kWh (25.841 kWh/day) -0.165 kWh (-0.078 kWh/day)
  - This Month 848.555 kWh (29.147 kWh/day) 697.259 kWh (23.950 kWh/day) -151.296 kWh (-5.197 kWh/day)
  - This Year 3.583 MWh (19.893 kWh/day) 3.267 MWh (18.140 kWh/day) -0.316 MWh (-1.753 kWh/day)
Yesterday 27.667 kWh (1.153 kW) 24.502 kWh (1.021 kW) -3.165 kWh (-0.132 kW)
Last 7 Days 155.234 kWh (22.176 kWh/day) 185.299 kWh (26.471 kWh/day) 30.065 kWh (4.295 kWh/day)
Last 30 Days (05/31/2026) 879.394 kWh (29.313 kWh/day) 703.031 kWh (23.434 kWh/day) -176.363 kWh (-5.879 kWh/day)
Last One Year 6.695 MWh (18.343 kWh/day) 7.728 MWh (21.174 kWh/day) 1.033 MWh (2.830 kWh/day)
Lifetime Since PTO 39.149 MWh (17.594 kW/day) 42.778 MWh (19.225 kW/day) 3.629 MWh (1.631 kW/day)
Lifetime Since Install 39.183 MWh 43.358 MWh 4.175 MWh
Voltage/Current 252.1 V / 0.0 A 252.1 V / 1.6 A 252.1 V / 1.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/21/2020 23:50 (13.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.005 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.888 2.184 9.976 0.000 kW
1.853 kWh
0.000 kW
11.119 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.856 2.132 9.760
03 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.892 2.182 9.954
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.897 2.206 10.013
05 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.761 2.028 9.284
06 - 202245****** IQ7+M [0] ---- 0.000 0.289 1.825 2.084 9.616
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.290 1.817 2.086 9.259 0.000 kW
1.835 kWh
0.000 kW
9.176 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.815 2.130 9.312
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 1.821 2.069 9.242
10 - 202244****** IQ7+M [0] ---- 0.000 0.291 1.862 2.143 9.464
11 - 202224****** IQ7+M [0] ---- 0.000 0.290 1.862 2.165 9.485
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.259 1.701 1.963 9.474 0.000 kW
1.677 kWh
0.000 kW
6.709 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.261 1.640 1.856 9.190
14 - 202216****** IQ7+ [0] ---- 0.000 0.260 1.700 1.959 9.514
15 - 202245****** IQ7+M [0] ---- 0.000 0.258 1.668 1.926 9.373
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.