Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.345 kW
03/22/2026 07:56 (2125 days) Production Consumption NET Usage
Now 0.399 kW 0.744 kW 0.345 kW
Today 2.553 kWh (0.321 kW) 3.011 kWh (0.379 kW) 0.458 kWh (0.058 kW)
  - This Week 2.553 kWh (7.708 kWh/day) 3.011 kWh (9.091 kWh/day) 0.458 kWh (1.383 kWh/day)
  - This Month 376.540 kWh (17.652 kWh/day) 340.030 kWh (15.940 kWh/day) -36.510 kWh (-1.712 kWh/day)
  - This Year 1.010 MWh (12.579 kWh/day) 1.440 MWh (17.924 kWh/day) 0.429 MWh (5.345 kWh/day)
Yesterday 25.529 kWh (1.063 kW) 14.676 kWh (0.611 kW) -10.853 kWh (-0.452 kW)
Last 7 Days 139.582 kWh (19.940 kWh/day) 132.652 kWh (18.950 kWh/day) -6.930 kWh (-0.990 kWh/day)
Last 30 Days (02/20/2026) 471.204 kWh (15.707 kWh/day) 458.709 kWh (15.290 kWh/day) -12.495 kWh (-0.416 kWh/day)
Last One Year 6.081 MWh (16.661 kWh/day) 7.894 MWh (21.627 kWh/day) 1.812 MWh (4.966 kWh/day)
Lifetime Since PTO 36.576 MWh (17.210 kW/day) 40.951 MWh (19.268 kW/day) 4.374 MWh (2.058 kW/day)
Lifetime Since Install 36.610 MWh 41.531 MWh 4.921 MWh
Voltage/Current 248.2 V / 1.6 A 248.3 V / 3.0 A 248.3 V / 1.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/16/2020 22:53 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.280 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.338 2.005 14.359 0.000 kW
2.242 kWh
0.000 kW
13.451 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.261 1.928 13.857
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.239 1.914 13.798
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.269 1.936 13.921
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.049 1.738 12.635
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.295 1.958 14.057
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 2.018 1.725 12.471 0.000 kW
2.103 kWh
0.000 kW
10.515 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.135 1.791 12.896
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 2.066 1.767 12.640
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.142 1.805 12.966
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.154 1.800 12.983
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.296 2.358 2.145 14.640 0.000 kW
2.329 kWh
0.000 kW
9.314 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.295 2.270 2.100 14.229
14 - 202216****** IQ7+ [5] VCOP 0.000 0.297 2.363 2.158 14.641
15 - 202245****** IQ7+M [5] VCOP 0.000 0.298 2.324 2.120 14.371
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 54.65 V Current/Power 170.57 A (9.322 kW)
Remain Capacity/Energy 576.3 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.8 % State Of Health 96.2 %
Run Time - to full Report Date 2020-06-16 23:42
voltag, current for each battery pack voltage, current, and SOC

Voltage 54.65 V Cell (MIN/MAX) 3.408 V / 3.422 V (0.014 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.1 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.8 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-16 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.417 V 3.408 V 3.416 V 3.409 V 3.418 V 3.411 V 3.411 V 3.419 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.418 V 3.410 V 3.419 V 3.411 V 3.421 V 3.412 V 3.421 V 3.422 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -