Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.299 kW
05/14/2026 10:15 (2178 days) Production Consumption NET Usage
Now 1.609 kW 0.310 kW -1.299 kW
Today 5.651 kWh (0.550 kW) 3.671 kWh (0.357 kW) -1.980 kWh (-0.193 kW)
  - This Week 112.952 kWh (25.507 kWh/day) 55.033 kWh (12.428 kWh/day) -57.919 kWh (-13.079 kWh/day)
  - This Month 331.027 kWh (24.652 kWh/day) 172.170 kWh (12.822 kWh/day) -158.857 kWh (-11.830 kWh/day)
  - This Year 2.284 MWh (17.118 kWh/day) 2.232 MWh (16.727 kWh/day) -0.052 MWh (-0.391 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 173.141 kWh (24.734 kWh/day) 127.703 kWh (18.243 kWh/day) -45.438 kWh (-6.491 kWh/day)
Last 30 Days (04/14/2026) 707.129 kWh (23.571 kWh/day) 431.409 kWh (14.380 kWh/day) -275.720 kWh (-9.191 kWh/day)
Last One Year 6.318 MWh (17.311 kWh/day) 7.792 MWh (21.348 kWh/day) 1.474 MWh (4.037 kWh/day)
Lifetime Since PTO 37.850 MWh (17.375 kW/day) 41.743 MWh (19.162 kW/day) 3.893 MWh (1.787 kW/day)
Lifetime Since Install 37.884 MWh 42.323 MWh 4.439 MWh
Voltage/Current 250.4 V / 6.4 A 250.3 V / 1.2 A 250.4 V / -5.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/04/2020 23:40 (12.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.882 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.964 1.419 8.024 0.000 kW
1.932 kWh
0.000 kW
11.591 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.934 1.400 7.926
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.964 1.414 8.065
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.955 1.407 8.040
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.890 1.379 7.758
06 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.884 1.393 7.836
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.989 1.385 7.746 0.000 kW
2.000 kWh
0.000 kW
10.000 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.979 1.366 7.778
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.968 1.386 7.730
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.030 1.394 7.923
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.034 1.385 7.902
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.235 1.599 1.225 7.097 0.000 kW
1.573 kWh
0.000 kW
6.291 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.233 1.531 1.222 6.985
14 - 202216****** IQ7+ [5] VCOP 0.000 0.235 1.597 1.230 7.157
15 - 202245****** IQ7+M [5] VCOP 0.000 0.229 1.564 1.209 7.041
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.60 V Current/Power 179.94 A (10.365 kW)
Remain Capacity/Energy 587.1 Ah (30.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.3 % State Of Health 98.5 %
Run Time 1m to full Report Date 2020-09-04 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.60 V Cell (MIN/MAX) 3.587 V / 3.607 V (0.020 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 195.7 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.3 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-04 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.596 V 3.592 V 3.601 V 3.597 V 3.600 V 3.602 V 3.600 V 3.603 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.601 V 3.600 V 3.601 V 3.602 V 3.602 V 3.601 V 3.587 V 3.607 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -