Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.005 kW
03/22/2026 06:20 (2125 days) Production Consumption NET Usage
Now 0.317 kW 0.312 kW -0.005 kW
Today 2.013 kWh (0.317 kW) 2.546 kWh (0.401 kW) 0.533 kWh (0.084 kW)
  - This Week 2.013 kWh (7.606 kWh/day) 2.546 kWh (9.620 kWh/day) 0.533 kWh (2.014 kWh/day)
  - This Month 376.000 kWh (17.682 kWh/day) 339.565 kWh (15.968 kWh/day) -36.435 kWh (-1.713 kWh/day)
  - This Year 1.010 MWh (12.582 kWh/day) 1.439 MWh (17.933 kWh/day) 0.429 MWh (5.351 kWh/day)
Yesterday 25.529 kWh (1.063 kW) 14.676 kWh (0.611 kW) -10.853 kWh (-0.452 kW)
Last 7 Days 139.264 kWh (19.895 kWh/day) 133.100 kWh (19.014 kWh/day) -6.164 kWh (-0.881 kWh/day)
Last 30 Days (02/20/2026) 470.664 kWh (15.689 kWh/day) 458.749 kWh (15.292 kWh/day) -11.915 kWh (-0.397 kWh/day)
Last One Year 6.081 MWh (16.660 kWh/day) 7.894 MWh (21.627 kWh/day) 1.813 MWh (4.967 kWh/day)
Lifetime Since PTO 36.576 MWh (17.210 kW/day) 40.950 MWh (19.268 kW/day) 4.375 MWh (2.058 kW/day)
Lifetime Since Install 36.610 MWh 41.530 MWh 4.921 MWh
Voltage/Current 248.7 V / 1.3 A 248.5 V / 1.3 A 248.6 V / -0.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/22/2020 23:56 (13.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.664 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.601 1.888 10.455 0.000 kW
1.583 kWh
0.000 kW
9.499 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.580 1.856 10.245
03 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.603 1.892 10.446
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.600 1.897 10.496
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.542 1.761 9.767
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.573 1.825 10.086
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.531 1.817 9.835 0.000 kW
1.568 kWh
0.000 kW
7.841 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.301 1.583 1.815 9.901
09 - 202217****** IQ7+ [0] ---- 0.000 0.298 1.530 1.821 9.824
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.592 1.862 10.072
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.605 1.862 10.086
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.239 1.342 1.701 9.730 0.000 kW
1.331 kWh
0.000 kW
5.324 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.238 1.312 1.640 9.387
14 - 202216****** IQ7+ [0] ---- 0.000 0.239 1.346 1.700 9.755
15 - 202245****** IQ7+M [0] ---- 0.000 0.236 1.325 1.668 9.596
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.