Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.208 kW
03/22/2026 06:01 (2125 days) Production Consumption NET Usage
Now 0.317 kW 0.525 kW 0.208 kW
Today 1.908 kWh (0.317 kW) 2.418 kWh (0.402 kW) 0.510 kWh (0.085 kW)
  - This Week 1.908 kWh (7.604 kWh/day) 2.418 kWh (9.637 kWh/day) 0.510 kWh (2.033 kWh/day)
  - This Month 375.895 kWh (17.688 kWh/day) 339.437 kWh (15.973 kWh/day) -36.458 kWh (-1.716 kWh/day)
  - This Year 1.010 MWh (12.583 kWh/day) 1.439 MWh (17.934 kWh/day) 0.429 MWh (5.351 kWh/day)
Yesterday 25.529 kWh (1.063 kW) 14.676 kWh (0.611 kW) -10.853 kWh (-0.452 kW)
Last 7 Days 139.256 kWh (19.894 kWh/day) 133.087 kWh (19.012 kWh/day) -6.169 kWh (-0.881 kWh/day)
Last 30 Days (02/20/2026) 470.559 kWh (15.685 kWh/day) 458.718 kWh (15.291 kWh/day) -11.841 kWh (-0.395 kWh/day)
Last One Year 6.081 MWh (16.660 kWh/day) 7.894 MWh (21.626 kWh/day) 1.813 MWh (4.967 kWh/day)
Lifetime Since PTO 36.575 MWh (17.210 kW/day) 40.950 MWh (19.268 kW/day) 4.375 MWh (2.058 kW/day)
Lifetime Since Install 36.609 MWh 41.530 MWh 4.921 MWh
Voltage/Current 248.7 V / 1.3 A 248.6 V / 2.1 A 248.6 V / 0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/01/2020 23:31 (12.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.494 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 0.732 1.065 10.442 0.000 kW
0.727 kWh
0.000 kW
4.361 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.295 0.724 1.054 10.288
03 - 202224****** IQ7+M [0] ---- 0.000 0.288 0.737 1.074 10.483
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 0.729 1.062 10.479
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 0.716 1.002 9.982
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 0.724 1.026 10.115
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 0.700 1.002 10.123 0.000 kW
0.704 kWh
0.000 kW
3.518 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 0.700 0.977 10.122
09 - 202217****** IQ7+ [0] ---- 0.000 0.287 0.704 1.008 10.104
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 0.710 1.022 10.361
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 0.704 1.012 10.347
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.225 0.650 0.982 9.247 0.000 kW
0.654 kWh
0.000 kW
2.615 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.223 0.646 0.981 9.040
14 - 202216****** IQ7+ [0] ---- 0.000 0.227 0.665 0.998 9.270
15 - 202245****** IQ7+M [0] ---- 0.000 0.229 0.654 0.986 9.118
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.92 A (10.366 kW)
Remain Capacity/Energy 589.2 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Run Time - to full Report Date 2020-09-01 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.