Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.445 kW
05/14/2026 08:10 (2178 days) Production Consumption NET Usage
Now 0.796 kW 0.351 kW -0.445 kW
Today 2.974 kWh (0.364 kW) 2.741 kWh (0.335 kW) -0.233 kWh (-0.028 kW)
  - This Week 110.275 kWh (25.402 kWh/day) 54.103 kWh (12.463 kWh/day) -56.172 kWh (-12.939 kWh/day)
  - This Month 328.350 kWh (24.613 kWh/day) 171.240 kWh (12.836 kWh/day) -157.110 kWh (-11.777 kWh/day)
  - This Year 2.281 MWh (17.109 kWh/day) 2.231 MWh (16.731 kWh/day) -0.050 MWh (-0.378 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 174.431 kWh (24.919 kWh/day) 127.231 kWh (18.176 kWh/day) -47.200 kWh (-6.743 kWh/day)
Last 30 Days (04/14/2026) 708.091 kWh (23.603 kWh/day) 432.281 kWh (14.409 kWh/day) -275.810 kWh (-9.194 kWh/day)
Last One Year 6.316 MWh (17.305 kWh/day) 7.792 MWh (21.348 kWh/day) 1.476 MWh (4.043 kWh/day)
Lifetime Since PTO 37.847 MWh (17.374 kW/day) 41.742 MWh (19.162 kW/day) 3.895 MWh (1.788 kW/day)
Lifetime Since Install 37.881 MWh 42.322 MWh 4.441 MWh
Voltage/Current 248.7 V / 3.2 A 248.8 V / 1.4 A 248.8 V / -1.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/19/2020 21:46 (9.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.067 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.249 0.933 1.015 4.381 0.000 kW
0.916 kWh
0.000 kW
5.494 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.248 0.916 1.004 4.390
03 - 202224****** IQ7+M [5] VCOP 0.000 0.249 0.917 1.012 4.417
04 - 202232****** IQ7+ [5] VCOP 0.000 0.249 0.881 0.985 4.280
05 - 202244****** IQ7+M [5] VCOP 0.000 0.251 0.925 1.022 4.312
06 - 202245****** IQ7+M [5] VCOP 0.000 0.248 0.923 1.003 4.153
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.072 1.185 4.969 0.000 kW
1.094 kWh
0.000 kW
5.471 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.008 1.131 4.526
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.149 1.308 5.439
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.145 1.284 5.377
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.096 1.205 5.086
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.127 0.503 0.452 2.475 0.000 kW
0.526 kWh
0.000 kW
2.102 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.128 0.539 0.519 2.698
14 - 202216****** IQ7+ [5] VCOP 0.000 0.129 0.537 0.511 2.614
15 - 202245****** IQ7+M [5] VCOP 0.000 0.127 0.524 0.496 2.604
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.45 V Current/Power 163.79 A (8.590 kW)
Remain Capacity/Energy 324.9 Ah (16.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 55.0 % State Of Health 98.5 %
Run Time 1h 37m to full Report Date 2020-11-18 17:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.