Date Offset  [+30][+10][+05][+01][-01][-05][-10]

Exporting to grid by 1.712 kW
01/30/2026 13:43 (2074 days) Production Consumption NET Usage
Now 1.731 kW 0.019 kW -1.712 kW
Today 9.403 kWh (0.685 kW) 7.653 kWh (0.558 kW) -1.750 kWh (-0.128 kW)
  - This Week 15.991 kWh (2.870 kWh/day) 75.107 kWh (13.479 kWh/day) 59.116 kWh (10.609 kWh/day)
  - This Month 221.889 kWh (7.503 kWh/day) 559.337 kWh (18.914 kWh/day) 337.448 kWh (11.411 kWh/day)
  - This Year 0.222 MWh (7.503 kWh/day) 0.559 MWh (18.914 kWh/day) 0.337 MWh (11.411 kWh/day)
Yesterday 5.645 kWh (0.235 kW) 11.666 kWh (0.486 kW) 6.021 kWh (0.251 kW)
Last 7 Days 28.266 kWh (4.037 kWh/day) 129.177 kWh (18.451 kWh/day) 100.911 kWh (14.414 kWh/day)
Last 30 Days 222.476 kWh (7.416 kWh/day) 568.292 kWh (18.943 kWh/day) 345.816 kWh (11.527 kWh/day)
Last One Year 6.080 MWh (16.658 kWh/day) 7.497 MWh (20.540 kWh/day) 1.417 MWh (3.881 kWh/day)
Lifetime Since PTO 35.788 MWh (17.250 kW/day) 40.071 MWh (19.315 kW/day) 4.283 MWh (2.065 kW/day)
Lifetime Since Install 35.821 MWh 40.651 MWh 4.829 MWh
Voltage/Current 252.4 V / 6.9 A 252.3 V / 0.1 A 252.4 V / -6.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/10/2026 23:50 (8.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.268 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.047 0.153 0.553 4.169 0.000 kW
0.148 kWh
0.000 kW
0.888 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.045 0.145 0.527 3.996
03 - 202224****** IQ7+M [5] VCOP 0.000 0.047 0.153 0.549 4.190
04 - 202232****** IQ7+ [5] VCOP 0.000 0.046 0.147 0.544 4.158
05 - 202244****** IQ7+M [5] VCOP 0.000 0.044 0.142 0.526 4.024
06 - 202245****** IQ7+M [5] VCOP 0.000 0.046 0.148 0.541 4.083
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.042 0.142 0.448 4.045 0.000 kW
0.143 kWh
0.000 kW
0.713 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.043 0.142 0.551 4.638
09 - 202217****** IQ7+ [5] VCOP 0.000 0.042 0.143 0.606 4.954
10 - 202244****** IQ7+M [5] VCOP 0.000 0.042 0.144 0.596 4.896
11 - 202224****** IQ7+M [5] VCOP 0.000 0.043 0.141 0.524 4.556
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.045 0.142 0.373 2.240 0.000 kW
0.157 kWh
0.000 kW
0.627 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.047 0.152 0.390 2.459
14 - 202216****** IQ7+ [5] -C-- 0.000 0.049 0.167 0.414 2.603
15 - 202245****** IQ7+M [5] VC-- 0.000 0.048 0.166 0.411 2.576
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.020 kWh
0.000 kW
0.039 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.015 0.039 0.241 1.620
Panel Layout Each Group Production

Charger History
Voltage PV 1.67 V Voltage Charge 52.39 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.1 °C / 23.8 °C Flags 00/00/00 Energy Today 0.822 kWh @ 2026-01-10 23:56
voltage in/out power and energy

Battery History
Voltage 52.58 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 316.5 Ah (16.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 53.4 % State Of Health 98.9 %
Run Time 10d 23h 44m to empty Report Date 2026-01-10 23:57
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.