Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.312 kW
02/03/2026 02:31 (2078 days) Production Consumption NET Usage
Now 0.000 kW 0.312 kW 0.312 kW
Today 0.000 kWh (0.000 kW) 1.307 kWh (0.515 kW) 1.307 kWh (0.515 kW)
  - This Week 42.561 kWh (20.208 kWh/day) 73.453 kWh (34.876 kWh/day) 30.892 kWh (14.668 kWh/day)
  - This Month 42.561 kWh (20.208 kWh/day) 73.453 kWh (34.876 kWh/day) 30.892 kWh (14.668 kWh/day)
  - This Year 0.288 MWh (8.699 kWh/day) 0.657 MWh (19.835 kWh/day) 0.369 MWh (11.136 kWh/day)
Yesterday 20.377 kWh (0.849 kW) 15.260 kWh (0.636 kW) -5.117 kWh (-0.213 kW)
Last 7 Days 82.057 kWh (11.903 kWh/day) 138.840 kWh (20.140 kWh/day) 56.783 kWh (8.237 kWh/day)
Last 30 Days 262.962 kWh (8.796 kWh/day) 612.907 kWh (20.503 kWh/day) 349.945 kWh (11.706 kWh/day)
Last One Year 6.110 MWh (16.746 kWh/day) 7.549 MWh (20.689 kWh/day) 1.439 MWh (3.944 kWh/day)
Lifetime Since PTO 35.854 MWh (17.253 kW/day) 40.168 MWh (19.329 kW/day) 4.314 MWh (2.076 kW/day)
Lifetime Since Install 35.888 MWh 40.748 MWh 4.860 MWh
Voltage/Current 251.2 V / 0.0 A 251.0 V / 1.2 A 251.1 V / 1.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/18/2020 23:00 (13.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.161 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.299 1.966 1.633 8.925 0.000 kW
1.921 kWh
0.000 kW
11.526 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.921 1.591 8.731
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.958 1.622 8.900
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.976 1.641 8.928
05 - 202244****** IQ7+M [0] ---- 0.000 0.300 1.816 1.484 8.243
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.889 1.560 8.644
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.301 1.848 1.501 8.086 0.000 kW
1.870 kWh
0.000 kW
9.349 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.300 1.857 1.463 8.097
09 - 202217****** IQ7+ [0] ---- 0.000 0.300 1.846 1.499 8.111
10 - 202244****** IQ7+M [0] ---- 0.000 0.300 1.900 1.511 8.269
11 - 202224****** IQ7+M [0] ---- 0.000 0.300 1.897 1.501 8.256
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.286 1.858 1.685 8.830 0.000 kW
1.821 kWh
0.000 kW
7.285 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.284 1.766 1.653 8.719
14 - 202216****** IQ7+ [0] V--- 0.000 0.281 1.848 1.686 8.901
15 - 202245****** IQ7+M [0] ---- 0.000 0.276 1.813 1.662 8.784
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.55 V Current/Power 164.07 A (8.622 kW)
Remain Capacity/Energy 361.8 Ah (18.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 62.7 % State Of Health 96.2 %
Run Time 1h 18m to full Report Date 2020-08-18 23:53
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.55 V Cell (MIN/MAX) 3.279 V / 3.289 V (0.010 V)
Current/Power -0.53 A (-28 W) Runtime 9d 9h 50m to empty
Remain Capacity/Energy 120.6 Ah (6.2 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 62.7 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-18 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.279 V 3.279 V 3.280 V 3.280 V 3.282 V 3.281 V 3.283 V 3.283 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.286 V 3.284 V 3.287 V 3.286 V 3.288 V 3.288 V 3.289 V 3.289 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -