Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.201 kW
05/14/2026 07:16 (2178 days) Production Consumption NET Usage
Now 0.443 kW 0.242 kW -0.201 kW
Today 2.434 kWh (0.335 kW) 2.559 kWh (0.352 kW) 0.125 kWh (0.017 kW)
  - This Week 109.735 kWh (25.500 kWh/day) 53.921 kWh (12.530 kWh/day) -55.814 kWh (-12.970 kWh/day)
  - This Month 327.810 kWh (24.642 kWh/day) 171.058 kWh (12.859 kWh/day) -156.752 kWh (-11.783 kWh/day)
  - This Year 2.281 MWh (17.110 kWh/day) 2.231 MWh (16.735 kWh/day) -0.050 MWh (-0.376 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 174.164 kWh (24.881 kWh/day) 127.372 kWh (18.196 kWh/day) -46.792 kWh (-6.685 kWh/day)
Last 30 Days (04/14/2026) 708.225 kWh (23.608 kWh/day) 432.556 kWh (14.419 kWh/day) -275.669 kWh (-9.189 kWh/day)
Last One Year 6.316 MWh (17.304 kWh/day) 7.793 MWh (21.350 kWh/day) 1.477 MWh (4.046 kWh/day)
Lifetime Since PTO 37.847 MWh (17.374 kW/day) 41.742 MWh (19.162 kW/day) 3.895 MWh (1.788 kW/day)
Lifetime Since Install 37.880 MWh 42.322 MWh 4.441 MWh
Voltage/Current 249.4 V / 1.8 A 249.3 V / 1.0 A 249.4 V / -0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/10/2020 19:24 (8.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.142 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.222 0.771 0.325 3.877 0.000 kW
0.763 kWh
0.000 kW
4.577 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.220 0.748 0.315 3.765
03 - 202224****** IQ7+M [5] VCOP 0.000 0.227 0.733 0.326 3.741
04 - 202232****** IQ7+ [5] VCOP 0.000 0.220 0.687 0.308 3.561
05 - 202244****** IQ7+M [5] VCOP 0.000 0.225 0.812 0.332 4.031
06 - 202245****** IQ7+M [5] VCOP 0.000 0.222 0.825 0.334 4.001
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.003 0.342 4.788 0.000 kW
0.834 kWh
0.000 kW
4.172 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.052 4.147
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 1.103 0.354 5.114
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.082 0.351 5.084
11 - 202224****** IQ7+M [5] VCOP 0.000 0.288 0.983 0.343 4.808
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.100 0.317 0.284 1.980 0.000 kW
0.348 kWh
0.000 kW
1.393 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.111 0.364 0.290 2.174
14 - 202216****** IQ7+ [5] VCOP 0.000 0.110 0.361 0.294 2.169
15 - 202245****** IQ7+M [5] VCOP 0.000 0.110 0.350 0.285 2.113
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.74 V Current/Power 167.86 A (9.020 kW)
Remain Capacity/Energy 498.3 Ah (25.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 84.3 % State Of Health 98.5 %
Run Time 33m to full Report Date 2020-12-10 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.74 V Cell (MIN/MAX) 3.352 V / 3.362 V (0.010 V)
Current/Power 4.00 A (0.215 kW) Runtime 7h 43m to full
Remain Capacity/Energy 166.1 Ah (8.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 84.3 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-10 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.352 V 3.355 V 3.354 V 3.356 V 3.356 V 3.357 V 3.359 V 3.358 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.357 V 3.360 V 3.359 V 3.361 V 3.360 V 3.362 V 3.362 V 3.361 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -