Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.233 kW
05/14/2026 06:42 (2178 days) Production Consumption NET Usage
Now 0.446 kW 0.213 kW -0.233 kW
Today 2.174 kWh (0.324 kW) 2.364 kWh (0.352 kW) 0.190 kWh (0.028 kW)
  - This Week 109.475 kWh (25.580 kWh/day) 53.726 kWh (12.553 kWh/day) -55.749 kWh (-13.026 kWh/day)
  - This Month 327.550 kWh (24.666 kWh/day) 170.863 kWh (12.867 kWh/day) -156.687 kWh (-11.799 kWh/day)
  - This Year 2.281 MWh (17.111 kWh/day) 2.231 MWh (16.736 kWh/day) -0.050 MWh (-0.375 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 173.939 kWh (24.848 kWh/day) 127.236 kWh (18.177 kWh/day) -46.703 kWh (-6.672 kWh/day)
Last 30 Days (04/14/2026) 708.210 kWh (23.607 kWh/day) 432.892 kWh (14.430 kWh/day) -275.318 kWh (-9.177 kWh/day)
Last One Year 6.316 MWh (17.304 kWh/day) 7.794 MWh (21.354 kWh/day) 1.478 MWh (4.050 kWh/day)
Lifetime Since PTO 37.846 MWh (17.374 kW/day) 41.741 MWh (19.163 kW/day) 3.895 MWh (1.788 kW/day)
Lifetime Since Install 37.880 MWh 42.321 MWh 4.441 MWh
Voltage/Current 249.9 V / 1.8 A 249.8 V / 0.9 A 249.9 V / -0.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/18/2020 21:37 (7.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.656 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.000 2.714 0.000 kW
0.001 kWh
0.000 kW
0.005 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.000 2.617
03 - 202224****** IQ7+M [5] VCOP 0.000 0.002 0.000 0.001 2.591
04 - 202232****** IQ7+ [5] VCOP 0.000 0.002 0.000 0.001 2.479
05 - 202244****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.001 2.758
06 - 202245****** IQ7+M [5] VCOP 0.000 0.003 0.004 0.001 2.817
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.002 0.000 0.002 3.233 0.000 kW
0.008 kWh
0.000 kW
0.038 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.002 0.000 0.001 0.056
09 - 202217****** IQ7+ [5] VCOP 0.000 0.006 0.012 0.007 3.442
10 - 202244****** IQ7+M [5] VCOP 0.000 0.007 0.017 0.008 3.416
11 - 202224****** IQ7+M [5] VCOP 0.000 0.006 0.008 0.005 3.179
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.028 0.111 0.050 1.517 0.000 kW
0.153 kWh
0.000 kW
0.613 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.024 0.074 0.040 1.632
14 - 202216****** IQ7+ [5] VCOP 0.000 0.020 0.063 0.036 1.633
15 - 202245****** IQ7+M [5] VCOP 0.000 0.090 0.365 0.130 1.681
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.44 V Current/Power 163.78 A (8.589 kW)
Remain Capacity/Energy 328.8 Ah (16.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 55.6 % State Of Health 98.5 %
Run Time 1h 36m to full Report Date 2020-12-18 23:33
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.44 V Cell (MIN/MAX) 3.272 V / 3.282 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 9d 3h 39m to empty
Remain Capacity/Energy 109.6 Ah (5.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 55.6 % State Of Health 98.5 %
Temperature 21.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-18 23:33
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.272 V 3.273 V 3.274 V 3.274 V 3.275 V 3.276 V 3.276 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.278 V 3.278 V 3.279 V 3.279 V 3.280 V 3.280 V 3.281 V 3.282 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -