Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.498 kW
11/04/2025 13:51 (1987 days) Production Consumption NET Usage
Now 2.789 kW 0.291 kW -2.498 kW
Today 14.910 kWh (1.074 kW) 5.056 kWh (0.364 kW) -9.854 kWh (-0.710 kW)
  - This Week 38.727 kWh (15.022 kWh/day) 45.485 kWh (17.643 kWh/day) 6.758 kWh (2.621 kWh/day)
  - This Month 55.665 kWh (15.556 kWh/day) 61.673 kWh (17.235 kWh/day) 6.008 kWh (1.679 kWh/day)
  - This Year 5.634 MWh (18.316 kWh/day) 6.394 MWh (20.788 kWh/day) 0.760 MWh (2.472 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.084 MWh (17.652 kW/day) 38.347 MWh (19.293 kW/day) 3.262 MWh (1.641 kW/day)
Lifetime Since Install 35.118 MWh 38.927 MWh 3.808 MWh
Voltage/Current 250.9 V / 11.1 A 250.9 V / 1.2 A 250.9 V / -10.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/06/2020 23:42 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.431 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.512 2.262 12.837 0.000 kW
1.424 kWh
0.000 kW
8.542 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.444 2.213 12.480
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.425 2.208 12.483
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.449 2.220 12.506
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.246 2.019 11.626
06 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.467 2.223 12.562
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.288 1.230 1.995 11.361 0.000 kW
1.253 kWh
0.000 kW
6.266 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.261 2.076 11.738
09 - 202217****** IQ7+ [5] VCOP 0.000 0.285 1.247 2.025 11.561
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.268 2.077 11.825
11 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.259 2.076 11.789
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.660 2.062 12.572 0.000 kW
1.656 kWh
0.000 kW
6.622 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.264 1.652 1.990 12.284
14 - 202216****** IQ7+ [5] VCOP 0.000 0.264 1.667 2.064 12.612
15 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.643 2.027 12.381
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.05 V Current/Power 180.06 A (10.272 kW)
Remain Capacity/Energy 577.2 Ah (29.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-06 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.05 V Cell (MIN/MAX) 3.520 V / 3.616 V (0.096 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.4 Ah (9.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 23
MOSFET CFET = OFF, DFET = ON Reported 2020-07-06 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.521 V 3.614 V 3.520 V 3.599 V 3.539 V 3.606 V 3.612 V 3.571 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.520 V 3.616 V 3.529 V 3.609 V 3.542 V 3.578 V 3.537 V 3.529 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -