Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.730 kW
11/04/2025 13:20 (1987 days) Production Consumption NET Usage
Now 3.003 kW 0.273 kW -2.730 kW
Today 13.399 kWh (1.003 kW) 4.901 kWh (0.367 kW) -8.498 kWh (-0.636 kW)
  - This Week 37.216 kWh (14.559 kWh/day) 45.330 kWh (17.733 kWh/day) 8.114 kWh (3.174 kWh/day)
  - This Month 54.154 kWh (15.226 kWh/day) 61.518 kWh (17.297 kWh/day) 7.364 kWh (2.071 kWh/day)
  - This Year 5.632 MWh (18.312 kWh/day) 6.394 MWh (20.789 kWh/day) 0.762 MWh (2.477 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.083 MWh (17.651 kW/day) 38.347 MWh (19.293 kW/day) 3.264 MWh (1.642 kW/day)
Lifetime Since Install 35.117 MWh 38.927 MWh 3.810 MWh
Voltage/Current 250.2 V / 12.0 A 250.2 V / 1.1 A 250.2 V / -10.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/22/2020 21:58 (12.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.166 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.470 2.043 13.060 0.000 kW
1.419 kWh
0.000 kW
8.514 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.427 1.969 12.736
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.438 1.969 12.826
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.444 1.990 12.859
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.301 1.806 12.045
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.433 1.986 12.799
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.315 1.780 11.757 0.000 kW
1.316 kWh
0.000 kW
6.578 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.308 1.860 12.263
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.318 1.804 11.954
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.324 1.870 12.345
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.314 1.874 12.364
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.279 1.521 2.028 12.177 0.000 kW
1.518 kWh
0.000 kW
6.073 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.278 1.511 1.942 11.735
14 - 202216****** IQ7+ [5] VCOP 0.000 0.278 1.530 2.024 12.201
15 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.511 1.990 12.009
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.70 V Current/Power 164.56 A (8.672 kW)
Remain Capacity/Energy 202.8 Ah (10.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 35.1 % State Of Health 96.2 %
Run Time 2h 16m to full Report Date 2020-07-22 23:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.70 V Cell (MIN/MAX) 3.287 V / 3.300 V (0.013 V)
Current/Power -0.55 A (-28 W) Runtime 5d 2h 54m to empty
Remain Capacity/Energy 67.6 Ah (3.5 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 35.1 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-22 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.287 V 3.289 V 3.289 V 3.290 V 3.290 V 3.291 V 3.291 V 3.292 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.293 V 3.294 V 3.294 V 3.296 V 3.297 V 3.298 V 3.299 V 3.300 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -